MOUNTING OF CONTROL PANEL
Adjust the location of the control panel with reference to the length of the
cable between the boiler and the panel.
The control panel should be located at least 1 metre above the floor, but
not too high towards the ceiling. Nor should it be located on an outer wall
or close to objects that give off heat, for example, CD player, refrigerator or
lamps, as this can give incorrect indication of temperature.
If, nevertheless, the control panel must be, or has been, mounted in the
vicinity of objects that emit heat, an external temperature sensor should be
connected to the control panel.
For making holes, see the accompanying instructions in the panel's
packaging.
All manuals and user guides at all-guides.com
Cable connection between
boiler and control panel
Connect the equipment in accordance
with Fig H. The colours are shown
with flag on the cable.
Fig H
1.
Outdoor sensor – blue (F)
2.
Colour sensor – white (G)
3.
Overload protection – green (E)
4.
Window circuit breaker – red (I)
5.
External start of boiler – yellow (D)
H
Black
6
7
Red
8
Blue
9
Grey
10
1
2
3
4
1
2
3
4
5
5
21