Mount the bracket in the wall in upright position above the water
container (which contains a solution of EC reducing acid and
water).
Place the pump in vertical position (with the tubes below) on the
wall, above and centered with the "Mounting bracket". Then go
down the pump until it is joined with the bracket.
Connect the pump to the MC311 EC controller (on the black and
white outlet). The pump will discharge 0,08 cL every 2 seconds
when active.
Place the plug and B/W outlet far away from water!
Before servicing (maintenance) on the pump (e.g. changing
tube), please disconnect the equipment.
It is suggested to dissolve 10 cL of Mono-nutrient in a 5L container of water. Depending
on the volume of your tank and the brand of your Mono-nutrient (and whether it is more
or less concentrated), this quantity can be increased later. It is better to dissolve more
than less. It is suggested to use an airstone on the bottom of your tank. The pump can
be attached directly to the container of the solution.
OPTIONAL ACCESSORIES:
M10000B
Electrode rinse solution, 20 ml sachet (25 pcs)
1413 μS/cm calibration solution, 20 ml sachet (25 pcs)
M10031B
M10032B
1382 ppm calibration solution, 20 ml sachet (25 pcs)
1413 μS/cm calibration solution, 230 ml bottle
MA9061
MA9062
1382 ppm calibration solution, 230 ml bottle
WARRANTY:
These instruments are warranted from all defects in materials and manufacturing for a period of two years
from the date of purchase. The electrode is warranted for a period of 6 months.
If during this period, the repair or replacement of parts is required, where the damage is not due to negli-
gence or erroneous operation by the user, please return the parts to either dealer or our office and the repair
will be effected free of charge.
Note: We reserve the right to modify the design, construction and appearance of our products without ad-
vance notice.
www.milwaukeeinstruments.eu
USER MANUAL
MILWAUKEE MC311 EC CONTROLLER
WITH MP810 1,5 L/H DOSING PUMP
mS
1.8
SPECIFICATIONS
MC311 EC Meter
Range
0.0 to 10.0 mS
Resolution
0.1 mS
±2% Full scale
Accuracy
Setpoint
0.8 to 2.8 mS
Alarm / Output
active when measure is
Power Socket
higher/lower than selected
setpoint depending on
user selection
Power drivers
115VAC, 2A, 60Hz
or 230VAC, 1A, 50Hz
pH electrode
MA812/2 (included)
0 to 50°C, 95% RH
Environment
not condensing
Power supply
12 VDC (included)
Dimensions
148.5 x 82.5 x 32 mm
Weight
180 g
MC740
MP810 Peristaltic Dosing Pump
• Constant Dosing flow of 1,5 l/h
(25 cc/min)
• No regulation
• Maximum pressure: 1 bar
• Made of Polipropilene (PP)
• Peristaltic tube in Santoprene
• Power supply: 230 VAC ± 10%