PROBLEMS
The air conditioner
doesn't work
The air conditioner
works for a short
time only
The air conditioner
works but doesn't
cool the room
.-,
---V.
CAUSES
the power is off
the fan is blocked
the security device was triggered
the security float was triggered
the exhaust hose is twisted
the exhaust hose is blocked
the drain hose is bent
windows open
a heat source is operating in the room (bur-
ner, light, etc.) or there are a lot of people
air filters clogged
conditions or size of the room
Strange odour in the . •
air filters dirty
room
Leaking condensa-
tion from the unit
around of the con-
ditioner
The air conditioner doe- .
sn't work for about 3
minutes from luming on
lhe appliance
The warning light
.
E® is on
incorrect installation of the appliance
SOLUTIONS
wait
plug in the appliance
call the Service Centre
call the Service Centre
empty the basin
position exhaust tube correctly
check if there are obstacles
blocking the exhaust of air out
of the appliance
unbend the tube
close the open window
remove the heat source
clean the filter or replace
clean the filter or replace it
empty the basin and drain the
water with the drainage tube
found on the back side of the
appliance
the appliance
the appliance's security system has interve-
wait for 3 minutes
ned
condensation collection basin is full
If the light is still on. consult the
Service Centre