EN
When the maxmimum pressure is reached, the tool stops automatically to save energy. The maximum
force indicator comes on.
•
Release the deadman's handle to bring it back to neutral position.
•
The tool can be operated again.
6.3.8
Environmental information
•
Under normal use, no leakage will occur. Therefore, there will be no contact with toxical substances
inside the battery pack.
•
Under normal use, no environmental hazard is present.
6.4
After use
6.4.1
Inspection
•
Check the battery level. Recharge the battery pack, if necessary. See section 3.6.2.
•
Check the unit for completeness, leaks and damage. Do not use the unit if it leaks or is damaged
and contact the Holmatro dealer.
•
Check the accessories used for completeness and damage. Replace them if the damage is
considerable.
•
Inspect the tips. Replace them if the damage is considerable.
•
Check the operation of the deadman's handle. It must return to the neutral position when you
release it.
•
Check that the carrying handle is firmly attached.
6.4.2
Shut down
•
Close the spreading arms with the spreading tips slightly opened. The tool can be stored without
pressure.
•
Stop the tool.
•
Remove the battery pack and put it on the battery charger.
•
It is also possible to charge the battery on the tool with the on-tool charge cable.
•
A battery pack can be put on the battery charger. It can also be connected via the on-tool charge
cable. If these two functions are used, the battery pack on the tool is charged first.
6.4.3
Storing the battery pack
NOTICE
When the battery pack is not in use, it is advised to keep the battery pack connected to the
battery charger (connected to a power source) at all times. When the battery pack is full, the
battery charger automatically switches on and off at regular intervals to keep the battery
level at 100%.
•
Store the battery pack in a dry and well-ventilated area. The maximum storage temperature of 40 °C
(104 °F) may not be exceeded.
•
Make sure the equipment can not fall over during transport.
50
916.400.139_002
PCT50