6. VEDLEGG
6.1 Koblingsskjemaer
ENP1MSC
COMP
BLK
CC
CS
CS
RED
L
N
RED BLU
L
N
MERKNADER:
1. AT : SENSOR FOR LUFTTEMPERATUR
2. COMP : KOMPRESSOR
3. CT : SENSOR FOR FORDAMPET TEMPERATUR
4. EEV : ELEKTRONISK EKSPANSJONSVENTIL
5. FM : VIFTEMOTOR
6. FS : VANNSENSOR
7. HP : HØYTRYKKSBRYTER
8. IT : TEMPERATURSENSOR TIL VANNINNLØP
All manuals and user guides at all-guides.com
CR
BLK
CR
FM
WHT
C1
RED
4V
OUT3
P1 P2
OUT4
OUT2
OUT5
AC-N
2
2
TC
12V
C2
1
N
3
5
7
01
2
4
6
8
BLU
EEV
5
OUT1
OUT2
Controller
FS
LP
HP
9. LP : LAVTRYKKSBRYTER
10. OT : TEMPERATURSENSOR TIL VANNUTLØP
11. SUT : SENSOR FOR SUGETEMPERATUR
12. TC : OMFORMER 230V
13. 4V : 4-VEIS VENTIL
14. C1 : KOMPRESSORKONDENSATOR
15. C2 : VIFTEKONDENSATOR
16. OUT2 : POTENSIALFRI KONTAKT, MAKS. 7A
GND
AI06
5K
AT
GND
t
AT
AI05
5K
CT
GND
t
CT
AI04
5K
OT
GND
t
OT
AI03
5K
IT
GND
t
IT
AI02
5K
SUT
GND
t
SUT
AI01
+5V
GND
/ 12V
17