8.3 Accessories / Tri-section plates
Type
Art� no�
Tri-Section 210
791210
Tri-Section 340
791340
Tri-Section 495
791495
8.4 Pumps in combination with HXP pullers
We advise to use pumps with min. oil capcaity of 500cc.
8.5 Explanation machine parts HXP
The parts drawing may be requested by sending an e-mail to info@bega.nl. State clearly
which type of puller you have
9. Troubleshooting
The machine should only be checked or repaired by qualified engineers.
Problem
Too little oil
Press cylinder does not
pressurize
Valve or pump worn
Seals worn
Press cylinder does not
Plunger crooked
retract
Oil comes out at the
front of the press
Seals worn
cylinder.
10
Cap.
Min shaft
Max shaft
ton
diameter
diameter
mm
mm
8
50
210
20
90
340
30
140
495
Cause
Top up the oil. Clamp the puller horizontally in the vice with the filler
cap facing upwards. Loosen the cap using an Allen key. Ensure that the
press cylinder is completely retracted. Fill the reservoir with hydraulic
oil ISO 46 up to the max.
Send the puller to your supplier for overhaul.
Send the puller to your supplier for overhaul.
If the plunger is crooked, the puller can no longer be repaired. Dispose
of the puller in accordance with the local disposal regulations.
Send the puller to your supplier for overhaul.
Max
Thickness
Weight
spread
mm
kg
mm
280
31
5,5
460
45
16,5
660
61
41
Solution
Use in combination
with
HXP63, 83
HXP83, 123, 203
HXP203, 303
© BETEX Tools