GB
IRL
Fault
Liquid flows out of the
pump.
The nozzle does not spray
even though pressure is
present.
safety valves blows off too
early.
The shut-off valve does not
close.
Liquid emerges without the
lever being activated.
Pressure gage is not
indicating any tank pressure.
Contact address for additional information → see title page.
Warranty
We guarantee that from the time it is first purchased for a period of the legally valid required warranty
period (maximum 3 years) this device will not exhibit any material or processing errors. If defects are
discovered during the warranty period, MESTO or the distributor in your country will repair the device
without charging for the labor or material or (at the discretion of MESTO) replace the device itself or its
defective parts.
If such defects are discovered, please contact us immediately. We require the invoice or cash register
receipt for purchase of the device.
The warranty does not include wearing parts (seals, O-rings, diaphragm, etc.) or defects which have
occurred due to improper use or unforeseeable circumstances.
CE Declaration of Conformity
according to EC Machinery Directive 2006/42/EC, Appendix II, No. 1A.
We,
MESTO Spritzenfabrik Ernst Stockburger GmbH
Ludwigsburger Straße 71
D-71691 Freiberg
declare under our sole responsibility that the products high-pressure spraying devices of the series
3565, 3585, 3595, 3615 from factory number 1289536 in the version supplied comply with all relevant
provisions of the Directive 2006/42/EC. Furthermore, the device complies with the Directive 97/23/EC
for pressure equipment.
Rolf Rehkugler, Ludwigsburger Str. 71, D- 71691 Freiberg, is authorized to compile the technical
documentation.
Freiberg, 15.12.2011
Bernd Stockburger
- Managing Director –
AUS
USA
Cause
Valve disk [23] dirty of defective.
Filter [22] and / or nozzle [21]
blocked.
Safety valve [12] is defective.
O-ring [24] on the pressure bolt not
greased.
Defective pressure bolt [25] or
O-ring [24].
Pressure gage [16] defective.
18
NZ
CDN
Remedy
Clean or replace the valve disk.
(Fig. 20).
Clean the filter or / and nozzle.
(Fig. 18 +19).
Replace safety valve. (Fig. 22).
Grease the O-ring of the pressure
bolt. (Fig. 23).
Replace the pressure bolt or O-ring.
(Fig. 23).
Sever attachments (at top, at
bottom, on right) [26]. (Fig. 24)
Open panel [27], unscrew pressure
gage [16] with wrench and replace.
(Fig. 24).
Insert fixing knob [28] (from the
spare parts pouch [3]), push to the
right and insert panel [27]. (Fig. 25).
IND