5.8 - Semi-automatic programming of Upper limit switch ("0") and Lower limit switch ("1")

ATTENTION! – Programming intended exclusively for rolling shutters that only have the mechanical block for the Upper limit
switch ("0"), or only the mechanical block for the Lower limit switch ("1").
Select below the appropriate procedure for your rolling shutter.
Warnings:
– This procedure overwrites previously adjusted heights with the new heights using this same procedure.
– Every time the motor is powered, 2 movements are performed if at least one transmitter and the limit switch heights are not in the memory.
– Memorizing the limit switches with this procedure, the two heights are controlled and updated constantly by the "limit switch self-update" function (see paragraph 7.3).
Before starting the procedure, bring the rolling shutter to the midpoint of its stroke.
01. Command a raise manoeuvre by keeping the s (or t) keys pressed and wait for the rolling shutter to stop automatically as result of the impact of the rigid anti-
intrusion springs against the structure (= upper limit switch "0"). Upon completion, release the key.
02. Command a lower manoeuvre by keeping pressed the t (or s) key and release the key when the rolling shutter is about 5 cm from your chosen lower limit switch
"1".
03. Keep the n key pressed and wait for the motor to perform 2 movements. Upon completion, release the key.
04. Keep the n key pressed again and wait for the motor to perform 4 movements. Upon completion, release the key.
05. Keep the t key pressed and wait for the motor to perform 2 movements. Upon completion, release the key.
06. Fine adjustment of the position: press the t and s keys several times until the rolling shutter reaches the "1" height you want (at each pulse the rolling shutter
moves a few millimetres).
07. Keep the n key pressed and wait for the motor to perform 3 movements. Upon completion, release the key.
01
03
2
5
sec.
06
fine regulation
Notes:
– When performing the procedure, at any time you can cancel it by keeping the n and t keys pressed simultaneously for 4 seconds. Otherwise, do not press any
key and wait 60 seconds for the motor to perform 6 movements.
– After this programming, the s key will command the Raise manoeuvre and the t key will command the Lower manoeuvre. During the Raising manoeuvre, the
rolling shutter will be stopped by the impact of the mechanical blocks against the structure (= upper limit switch "0"), while during the Lowering manoeuvre the
rolling shutter will stop at the lower limit switch ("1") established by the installer.
Before starting the procedure, bring the rolling shutter to the midpoint of its stroke.
01. Command a raise manoeuvre by keeping pressed the s (or t) key and release the key when the rolling shutter is about 5 cm from your chosen upper limit switch
"0".
02. Keep the n key pressed and wait for the motor to perform 2 movements. Upon completion, release the key.
03. Keep the n key pressed again and wait for the motor to perform 4 movements. Upon completion, release the key.
04. Keep the s key pressed and wait for the motor to perform 2 movements. Upon completion, release the key.
05. Fine adjustment of the position: press the t and s keys until the rolling shutter reaches the "0" height you want (at each pulse the rolling shutter moves a few
millimetres).
06. Keep the n key pressed and wait for the motor to perform 3 movements. Upon conclusion, release the key.
07. Command a lower manoeuvre by keeping the t (or s) key pressed and wait for the rolling shutter to stop automatically as result of the impact of the rigid anti-
intrusion springs against the structure (= lower limit switch "1"). Upon conclusion, release the key.
5.8.1 - PROCEDURE "A"
Select this procedure if the mechanical block is positioned at the upper limit switch "0"
"0"
04
5
sec.
07
3
"1"
5
sec.
5.8.2 - PROCEDURE "B"
Select this procedure if the mechanical block is positioned at the lower limit switch "1"
02
05
4
THE
END
END
"1"
2
5
sec.
English – 6