Adater disc
When
operating
the
WAMABs without sepa-
rating system, use the
disc with the notches
(Figure 4a).
Figure 4a
Then connect the WAMAB to the sewage canal, in doing
so press the HT pipe tightly against the adapter disc and
tighten the union nut. Now push the hose of the fitting
kit over the hose nozzle protruding inwards (Figure 5) and
secure it with the hose clamps provided.
Fig.
5
Attaching the hose
Then screw on the siphon with GEKA coupling to the free
drain support of the larger wash area. Align it to the rear
right (Figure 6).
Fig.
6
Mounting and aligning the odour connection
Now place the wash area on the container. Fold it up
and connect the hose to the GEKA coupling of the siphon
(Figure 7).
Fig.
7
Connecting the hose
After putting the wash area on again, the WAMAB is rea-
dy for use.
When
operating
the
WAMABs with a sepa-
rating system, use the
disc without the notches
(Figure 4a).
Figure 4b