Download Print deze pagina

Aqua Medic aquarius control Gebruiksaanwijzing pagina 7

Advertenties

There are five switching points per channel: Set Line 1: white + blue – Set Line 2: royal blue – Set Line 3:
blue – Set Line 4: red – Set Line 5: purple – Set Line 6: UV.
Adjustable are:
00:00 to 00:00 for time period setting
000% to 000% for adjustment of the brightness
Use the +/- buttons to adjust the values, by pressing "OK" you reach the next value, by pressing "M" you can
exit the switching point.
For example: If you set 6:00 to 6:30, 0% to 100%, then the light will light up from 6:00 and in 30 minutes
will go up to 100% brightness. This means that the brightness will increase about 3.33% every minute. At
6:30, 100% are reached.
If you set 6:00 to 8:00, 1% to 100% (or 100% to 1%), the brightness will increase or decrease by 0.83%
every minute.
If the light shall not get constantly brighter, set 6:00 to 18:00, 70% to 70%. Then it will light up at 70% for
12 hours.
If you set 21:00 to 5:00, 0% to 0%, then the light is off from 21:00 to 5:00 the next morning.
If the light should work as a moonlight at night, you should select maximum 1% during the dark phase. The
zooxanthellae of corals as well as the plants should not be encouraged for photosynthesis at night.
After all programs are set, press M to exit. All programs are saved now. If the dimmer is on, only the time is
displayed.
Hints:
1. Each setting time refers to the last setting, e. g. if the first setting is 06:00 to 07:00, then the next setting
can only start at 07:00. No time before 07:00 can be set.
2. The dimmer saves the settings, even if it is unplugged. If the dimmer is switched on again,
the last saved settings.
After disconnecting the power supply, it takes about one minute for the controller to turn on the connected
light.
6.
Warranty
Should any defect in materials or workmanship be found within 24 months of the date of purchase AB Aqua
Medic undertakes to repair, or at our option replace, the defective part free of charge – always provided the
product has been installed correctly, is used for the purpose that was intended by us, is used in accordance
with the operating instructions and is returned to us carriage paid. Proof of Purchase is required by
presentation of the original invoice or receipt indicating the dealer's name, the model number and date of
purchase. This warranty may not apply if any model or production number has been altered, deleted or
removed, unauthorised persons or organisations have executed repairs, modifications or alterations, or
damage is caused by accident, misuse or neglect. Please note that the product is not defective under the
terms of this Warranty where the product, or any of its component parts, was not originally designed and /
or manufactured for the market in which it is used. These statements do not affect your statutory rights as a
customer.
AB Aqua Medic GmbH - Gewerbepark 24 - 49143 Bissendorf/Germany
- Technical changes reserved – 11/2018