Technical Data; Specified Conditions Of Use; Safety Instructions - Gude GIS 100 Vertaling Van De Originele Gebruiksaanwijzing

Inhoudsopgave

Advertenties

ENGLISH
18

Technical Data

Welder GIS 100
Art. No ...............................................................................................................................................................................................20023
Service connection .......................................................................................................................................230 V ~ 50-60 Hz
Rated input voltage AC Voltage U
Protection ................................................................................................................................................................................ 16 A
Maximum rated input current I
Maximum effective input current I
Idle voltage U
...................................................................................................................................................................................85 V
0
Degree of protection ................................................................................................................................................................... IP 21S
Insulation class ........................................................................................................................................................................................ H
Welding current I
Operating voltage U
Material thickness ......................................................................................................................................................................1-5 mm
Regulated section .................................................................................................................................................... 20 A-100 A
Dimensions ......................................................................................................................................................... 280 x 116 x 176 mm
Weight ............................................................................................................................................................................... 5,019 kg
......................................................................................................................................................................................MMA
Switch-on timeX* ............................................................ ............................................100A~25% | 70A~60% | 50A~100%
Electrodes ...................................................................................................................................................................1,0-3,2 mm
* Actual working time and total working time ratio.
Switch-on time determined at 40°C using simulation
the safety measures stated in the service manual. Act
responsibly toward third parties.
In case of any doubts about connection and
operation refer please to our customer center
Specified Conditions Of Use
Welder in protective atmosphere for thermal connec-
tion of ferrous metals by melting edges and including
mixture
Do not use this product in any other way as stated
for normal use. Not observing general regulations
in force and instructions from this manual does not
make the manufacturer liable for damages.
Ambient temperature -10 °C - +40 °C
Relative air humidity max. 50 % (40 °C), 90% (20 °C)
Altitude above sea level max. 1000 m
The ambient environment must be free from
abnormal amounts of dust, acids, corrosive gases or
substances.
All manuals and user guides at all-guides.com
.......................................................................................................................................... 230 V
1
............................................................................................................................................. 19 A
1max
....................................................................................................................................... 9,5 A
1eff
...........................................................................................................................................................................100 A
2
................................................................................................................................................................ 22-24 V
2
Read and understand the
operating instructions before
using the appliance. Abide by all

Safety instructions

WARNING! Electric shock! There is a risk of
an injury caused by electric shock!
Operation is only allowed with a safety
switch against stray current (RCD max. stray
current of 30mA).
IP21 protection degree of the welder. The welder
must not be exposed to rain and moisture when
being operated or stored.
Check the voltage. Technical data given on the type
label must correspond with electric network voltage.
Insert the plug of the electrical cable in a socket of
suitable shape, voltage and frequency complying
with current regulations.
Use extension cables with a maximum length of 5
meters and with a cable cross-section of not less than
1.5 mm2. Use of extension cables of different length
and cross-section and also of adapters and multiple
sockets should be avoided.
Check the cable and/or socket for damages before
the appliance putting into operation.
Defective cable or plug may cause electric shock.