tem reconfirms the previously selected command.
press the button previously pressed at Point 02 to confirm the
chosen command once more.

8.2 - Locking / unlocking the automation

This function allows for sending, through the keypad, the
command for "locking" or for "unlocking" the automation.
I1I
Press the  button: the keypad will signal the "incorrect
I2I
combination" error.
Wait 10 seconds: • to lock the automa-
tion = enter "0-0". • to unlock the automation = enter "1-1".
I3I
Within 10 seconds enter any valid combination.
the  button to confirm the action selected at Point 02. If
the procedure was performed correctly, the keypad will emit
3 buzzes and the "L2" LED will indicate the operating status
(see Table 6).
TABLE 5 - Commands that can be associated with
the buttons  or 
"L1" LED signal
Command
STEP-BY-STEP (by default
1 flash + pause
paired with the  button)
2 flashes + pause
OPEN
3 flashes + pause
CLOSE
PARTIAL OPENING (by default
4 flashes + pause
paired with the  button)
5 flashes + pause
STOP
6 flashes + pause
COURTESY LIGHT
9 – English
I4I
Lastly,

8.3 - Erasing the entire memory

I1I
Press and hold button "T": the "L1" LED will remain lit;
wait for it to flash 3 times then release button "T" during the
I2I
third flash.
light pulses followed by 3 buzzes; after this, the LED on the
front will flash 5 times.
"recognition of the devices connected to the control unit", by
consulting the control unit manual.
At the end of this procedure, the device will have to be re-
programmed. Note – at the start of a new programming op-
I4I
Press
eration, the user can once again choose which mode to use
("Easy" o "Professional").

9 - WARNINGS FOR USE OF THE DEVICE

The device operates through numerical combinations that
l
the user must know and enter onto the keypad for sending
commands to the automation.
programmed combinations (and relative commands associ-
ated with them) should only be disclosed to users authorised
to operate the automation.
the command can be transmitted by pressing the command
button ( or ) associated with the relevant combination.
the entered combination is incorrect, the device emits a buzz.
Important! – After the third consecutive entry of the incorrect
combination, the system blocks the device's operation for 60
seconds. Therefore, the user who makes a mistake while en-
tering a combination should suspend the operation and wait
10 seconds before entering the combination again, starting
from the first digit.
At this stage, the "L1" LED will emit a series of
I3I
Lastly, rerun the procedure for the
For security reasons, the
l
After entering the combination,
l
While entering a combination, the user
l
If
l

Advertenties