Download Inhoudsopgave Inhoud Print deze pagina

General Information; Installation; Installation Procedure - Myson KICKSPACE 600E Installatie- En Onderhoudshandleiding

Inhoudsopgave

Advertenties

®
04
KICKSPACE
600E

2.0 General Information

l This MYSON KICKSPACE
installation in the cavity beneath kitchen cupboards on the
vacant floor space, or other similar locations.
l No rear access shall be available to the unit after installation.
l Before proceeding with the installation, the unit must be
correctly sized to meet the heat loss requirements of
the room.
l When installed under a kitchen unit consideration should be
given to storage of perishable goods in the cupboard above.
l A minimum of 25mm clear headroom is required above the
®
top of the KICKSPACE
l The unit should be mounted on a clean and level floor area
under the cupboard base.

3.0 Installation

It is recommended that careful thought be given to siting the
appliance within the room. Try to avoid being directly in front of the
heater for long periods. Consider where you may stand, at a work
surface or the like. Position the heater to deliver the benefit of its
warmth but not so as to overheat yourself.
THE HEATER MUST NOT BE LOCATED IMMEDIATELY BELOW A
FIXED SOCKET OUTLET.
The appliance is designed to fit behind the plinth board and below
the base shelf of a kitchen-type cupboard ie within the free plinth
space. Figure 1 below shows the MINIMUM size cupboard unit into
which the appliance may be fitted.
The appliance may be installed into a cupboard with dimensions
larger than those given above.

4.0 Installation Procedure

1. Cut a hole in the plinth board, to the dimensions given in
Figure 2.
2. The power supply cable must be routed from the connecting unit
into the plinth space. The cable shall be sufficiently long as to pass
through the plinth space and plinth board. This enables the
appliance to be subsequently withdrawn from the plinth if
maintenance is required. Ensure no sharp edges are present along
the power cable route.
3. The appliance can now be slid through the plinth board, until the
fascia panel abutts the outside of the plinth board. Screw the fascia
panel to the plinth board with the screws provided.
4. Connect the unit to the mains power supply in accordance with
the appropriate section of these instructions.
To remove the appliance from the plinth space, should maintenance
be required, disconnect mains power supply, unscrew fascia panel
and slide out the appliance.
These dimensions are for a 600mm wide by 100mm (min) high plinth.
If the appliance is to be fitted into a plinth greater in length than
specified then the hole shown in Figure 2 must be cut at least 22mm
from one end.
All manuals and user guides at all-guides.com
®
fan convector is designed for
when fitted.
l The KICKSPACE
®
fan convector is supplied with integral
controls including fan speed selector/winter switch.
l In summer mode the fan can be operated to circulate a flow
of air without any heat supply.
l Heat output performance is given in the Technical Data
section of this manual.
l Since KICKSPACE
®
units are supplied with fan speed control
it is important to size the unit to match the calculated heat
loss requirements of the room with the unit operating at the
low fan speed. The higher fan speed can then be used for
more rapid heating from cold in extreme conditions.
WARNING: THIS APPLIANCE MUST NOT BE INSTALLED IN A
BATHROOM OR OTHER SIMILAR HIGH HUMIDITY AREA.
Fig. 1 (Minimum Cupboard Size)
A
B
Unit Ref:
A - Width
600mm
B - Plinth Height
120mm
C - Base Shelf Overhang
75mm maximum
D - Depth
400mm
Fig. 2 (Mounting Hole)
If the supply cord on this appliance is damaged, it must be replaced
by a special cord which is only available from an Authorised Service
Agent, or your supplier. If replacement of the supply cord is found
to be necessary, the following should be noted.
Cord Ref No: 3kW - 68000282
C
D
30mm
95mm
(3kW)
540mm
(3kW)