9.
Overzicht van de SMS-commando's
Command 1)
Getst
Get Status
Setou1
Set Output 1
Setou2
Set Output 2
Setou3
Set Output 3
Rstou1
Reset Output 1
Rstou2
Reset Output 2
Rstou3
Reset Output 3
Setdd NN
Set output impulse duration
Addnum
Add new number
Delnum
Delete number
Getnum
Read number
Rstart
Restart
MaxnnN
Set Max numbers
note:
This MESSAGE command
support only new version
software
Function
Read Status
INP=3F OUT=00 Pulse (sec) 5
Outputs control
-
-
-
-
-
-
Settings
INP=3F OUT=00 Pulse (sec) 3
Phone Book Settings
NR 12 +3716149759 added
or
NR 12 +3716149759 exist
NR 12 +3716149759 deleted
or
NR12 +3716149759 not exist
NR167: +3716149759
INP=3F OUT=00 Pulse (sec) 5
MaxNN=60
Return message
Description
Input and output state,
pulse duration (output 3)
Set Output 1
Set Output 2
Set Output 3 – relay ON
Reset Output 1
Reset Output 2
Reset Output 3 – relay
OFF
Set output impulse
duration, NN= 00..99sec;
if NN=00, then latch mode
ADDNUM +3716149759
DELNUM +3716149759
GETNUM 001
001 – location in SIM
phone book
Restart (module work
after 2 min)
N from 1 to 9
N=1 – 30 numbers
N=2 – 60 numbers
(default)
...
N=8 – 240 numbers
N=9 – 250 numbers
5