Malfunctions
Malfunction
Machine without function
Electric suction brush does not turn
Poor suction performance
Odor formation
Technical data
Machine
Rated voltage
Frequency
Rated power, nominal
Dimensions (LxWxH)
Main cord length
Maximum weight of operational machine
Values according to IEC 60335-2-69
Sound pressure level LpA
Uncertainty KpA
Vibration
Uncertainty K
Splash water guard
Protection class
Possible causes
Machine is switched off
No power supply
Main cord defect
Defective ON/OFF switch
Motor does not turn
Machine not in the working position
Motor is turning, but the brush is not
Motor protection filter soiled
Hose or dust nozzle blocked (e.g.
bits of wood, bits of fabric)
Double filter paper bag full
Cover of the suction unit not placed
correctly
Hose not correctly installed
Accessory not installed correctly
Moist double filter paper bag
Accumulation of moisture
jet 38
220-240V~
50-60
880
26x38x120
12.5
7.8
Troubleshooting
• Switch on the ON/OFF switch
• Insert the power supply plug into
the mains socket
• Replace the main cord
• Contact your service partner
• Contact your service partner
• Bring the machine into the working
position
• Drive defect
• Contact your service partner
• Clean or replace motor protection
filter
• Remove any foreign matter
• Replace double filter paper bag
• Check cover
• Check the hose
• Check accessory
• Store in dry location
• Replace the double filter paper
bag
jet 50
120V~
220-240V~
60
50-60
900
26x38x120
8.3
jet 38/50
69
2.5
<2.5
0.25
IPX0
II
Page
57
57
59
60
60
60
120V~
AC
60
Hz
W
cm
m
kg
dB(A)
dB(A)
m/s2
m/s2
63
EN