Functions and displays
Function of the LED
The LED displays the version number at the start by flashing.
The LED can then be used for IR programming (Step 3 Installation).
Over the next 30 minutes, the LED displays the detection and sending.
After this walk test period has elapsed, the LED is deactivated:
• to extend battery life
• to prevent someone from identifying the surveillance area during the day when the alarm
panel is deactivated.
Error and tamper monitoring
The detector continually monitors error and tamper states and reports all events to the receiver
component. The following is monitored:
• Tamper contact:
The detector's tamper contact is continually monitored.
• Battery voltage:
The detector monitors the battery voltage under load conditions and reports faults to the
receiver component.
• Supervision
The detector continually sends supervision messages to the alarm panel.