9. Electrical connection

Circuit diagram
EN
5
N
L
230 V ~
1 Thermostat
2 Bimetal thermal safety
3 Heating element
4 Control light
5 Connecting terminal

10. Commissioning

1.
2.
Only by a specialist!
Please observe:
• VDE 0100
1
• The installation must comply with current IEC and national local regulations or
ϑ
any particular regulations, specified by the local electricity supply company
• The rating plate and technical specifications
4
• The unit must be earthed!
3
A protective earth plug socket is required for connecting the device, which must be
freely accessible after the device has been installed.
2
If the water heater is to be connected permanently to AC mains circuit (connector sock-
ϑ >
et), an isolator with at least 3 mm separation on all poles must be used (e.g. via fuses).
The unit must not be installed with fixed connection cable.
1. Open hot water valve of the fitting or set single-lever mixer to »hot« until water
flows free of bubbles.
2. Only after step one plug in mains plug and select temperature.
Risk of running dry!
If you confuse the sequence, the temperature fuse will react. In this case you have
to fill the water heater with water and disconnect the electric supply for a short
time.
Changing hands
• Explain the function of the unit to the user, in particular, call his attention to the
safety instructions and the dripping of the fittings when heating up.
• Hand over the installation and operating instructions to the user.