DC voltage measurement

Set the selector switch to measurement range V=. Insert the black test lead
into the 'COM' socket and the red test lead into the right-hand socket. Using
the test probes, touch the test points of the test object. The multimeter
automatically searches for the most suitable measurement range. Read
measurement value on the display.
Volts DC
Range
200 mV
2 V
20 V
200 V
600 V
Input impedance: 10 MΩ.
Max. input voltage 600 V DC.
®
Testboy
TB-3000
Resolution
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
Operation
Accuracy
± 0.5 % of rdg. + 3 digits
± 0.8 % of rdg. + 5 digits