Damper "A"
open
fig. 15- Example of installation in the winter period
6.4 Securing and connections of this appliance
The product must be installed on a stable, flat floor that is not
subject to vibrations.
6.5 Hydraulic connections
Connect the cold water supply line and the outlet line to the ap-
propriate connection points (fig. 16).
The table below gives the characteristics of the connection
points.
Ref.
Function
1
Cold water inlet
2 *
Solar coil outlet
3 *
Solar coil inlet
4
Recirculation
5
Hot water outlet
6
Condensate drain
Pit for solar probe and ther-
A *
mal cut-out bulb
*: only for EKHHE200PCV37 and EKHHE260PCV37 models.
User, Installations and Maintenance Manual
Damper "B"
closed
Internal
compartment
Model 200 l / 260 l
1"G
3/4"G
3/4"G
3/4"G
1"G
1/2"G
1/2"G
6
B
4
3
2
The following figure (fig. 17) illustrates an example of plumbing
connection.
OUT
IN
fig. 17- Example of water system
Legend (fig. 17)
1 Water inlet pipe
4 Recirculation water inlet
5 Hot water outlet pipe
9 Inspectionable end of dis-
charge pipe
10 Pressure gauge
11 Shut-off valve
12 Pressure regulator
5
A
1
fig. 16
13 Safety valve
14 Expansion vessel
15 Drain tap
16 Recirculation pump
17 Spring check valve
18 Automatic thermostat mix-
ing equipment