OPERATING INSTRUCTIONS / ENGLISH
TECHNICAL SPECIFICATIONS
lithium pack rcB
1200 (LZ Type 010)
lithium pack rcB
1800 (LZ Type 020)
USB charging
Input: 5 VDC / 1A
cable (USB Charge
Cord Type 1)
FIRST USE AND CHARGING
Important note:
Charge the lithium packs prior to their first use!
Charging process
1. Connect the USB charging cable (Fig.°2.1) with a USB power
supply unit (5 V, 1 A, not included in delivery) and plug the USB
power supply unit into a socket. The charge indicator (Fig. 2.2)
will light up green.
2. Remove the contact protector (Fig. 1.4) and connect both
lithium packs to the charging plugs of the charging cable
(Fig. 2.3). Please refer to the diagram on the charging plugs
for correct orientation. The lithium packs can be charged in any
operating mode.
3. The charging process starts after one-time operation of the
control button (Fig. 1.3.).
4. The charge indicator (Fig. 2.2) will light up red during the
charging process.
5. Once the lithium packs are fully charged, the charging process
automatically ends and the charge indicator (Fig. 2.2) changes
back to green.
6. The charging status can be monitored with the LEDs on the lithium
pack, which light up successively as the charge increases, or
using the Lenz heat app* which offers convenient control.
– 148 –
Output: 3.7 V /
2400 mAh
Output: 3.7 V /
3600 mAh
Output: 4.2 VDC
/ 0,9A
7. After the end of the charging process, please disconnect both
lithium packs from the charging plugs.
Important note:
■
Because naturally occurring minimal differences due to
production can occur, the charge indicator in the Lenz heat
app* only serves as a general indicator.
■
Charge the product after every use.
This helps extend the life of the lithium packs and ensures
that the product is ready for use at any time.
■
The battery consists of lithium ion cells and can be
charged in any state.
For this reason, the battery does not need to be fully
discharged before charging.
The full charging capacity of the product can only be
■
conserved if the product is disconnected from the charging
plugs after the end of the charging process.
lithium pack rcB
1200
Charging time
lithium pack rcB
1800
SAFETY FUNCTIONS
Short circuit protection: In the event of a short circuit at
■
the contact or the heating element, the integrated electronics
automatically turn the product off. After removing the short
circuit, please briefly connect the lithium packs to the charging
plugs. Next, press the control button once and the product is
ready again.
■
Protection against overcharging and exhaustive discharge:
The product is protected against overcharging and exhaustive
– 149 –
5 – 7 h
7 – 9 h