Resistance Auto-ranging
Range
400.0 Ω
Continuity:
Frequency (for ACA)
Range
400 Hz
Min. Input Frequency:
Sensitivity:
ACA
Range
400 A
1000 A
1500 A
400 A
1000 A
1500 A
AC Conversion Type: * add 2 digits to accuracy when reading less
15% of full scale.
AC Conversions are ac-coupled, true rms responding, calibrated to the rms
value of a sine wave input. Accuracies are given for sine wave at full scale
and non-sine wave below half scale. For non-sine wave add the following
Crest Factor corrections:
For Crest Factor of 1.4 to 2.0, add 1.0% to accuracy.
12
Resolution
100 mΩ
Built-in buzzer sound when resistance is less
than 30 Ω approximately.
Resolution
1 Hz
3A rms for < 400Hz
Resolution
Accuracy
±(1.5% reading
0.1A
+ 5 digits) *
±(1.9% reading
1 A
+ 7 digits)
±(2.5% reading
1 A
+ 7 digits)
±(1.9% reading
0.1 A
+ 5 digits) *
±(2.5% reading
1 A
+ 7 digits)
±(3.0% reading
1 A
+ 7 digits)
Accuracy
±(1.0% reading
+ 3 digits)
Accuracy
±(0.1% reading
+ 2 digits)
20Hz
Frequency
Response
50 Hz ~ 60 Hz
61 Hz ~ 400 Hz
61 Hz ~ 200 Hz
Over voltage
protection
600 V rms
Over voltage
protection
AC/DC 1000 A
for 1 min.
Overload
protection
1500 A rms