Maintenance and cleaning
Cleaning the device
NOTE
Do not use aggressive cleaning agents or chemical solutions. These agents can damage the housing, impair the func-
tion of the device and harm animals, plants and the environment.
Clean the device only with clear water and a soft brush or sponge.
Replacing the membrane
• Only use original spare parts from PfG.
– The unit may be damaged by the use of spare parts from other manufacturers.
How to proceed:
D
1. Insert the membrane key with the notches onto the ring nut and unscrew the ring nut counter clockwise.
2. Remove the membrane and O-ring, check for damage, clean and, if necessary, replace.
3. Reassemble the unit in the reverse order.
– Ensure that the O ring is correctly positioned.
4. Reconnect to the power supply and check the function.
Storage/winter protection
If the ambient temperature leaves the permissible temperature range, uninstall the unit. (→ Technical data)
• Store the unit in a dry and frost-free place.
Malfunction remedy
Malfunction
LEDs are not lit
Illuminating power decreasing
No mist generated
Technical data
PondoFog RGB
Transformer
Connection voltage
Power frequency
Max. power consumption
Output voltage
Max. power output
Protection type
Length of power cable
Weight
Misting unit with
Connection voltage
LED
Power consumption
Protection type
Max. immersion depth
LED color space
Misting unit water consumption
Permissible water temperature
Connection cable length
Dimensions (Ø × H)
Weight
Cause
Power supply interrupted
Transformer defective
Bulb defective
Lamp glass soiled
Membrane worn
V AC
Hz
W
V AC
VA
m
kg
V AC
W
m
–
l/h
°C
m
mm
kg
Remedy
Check power supply
Replace transformer
Bulbs cannot be replaced. Dispose of bulbs.
Clean
Replace membrane
230-240
50
23
24
24
IP44
2
0.65
24
23
IP68
1
RGB
0.5
+4 ... +35
8
120 × 75
0.35
- EN -
9