Short manual
IMPORTANT INFORMATION
The battery inverter may only be installed, maintained and repaired by a trained and qualified
electrician. The electrician is responsible for ensuring that the applicable standards and
regulations are observed and implemented. Work that could affect the electrical power
system of the relevant energy supply company at the site of the solar power feed-in, may
only be carried out by qualified electricians expressly authorised (licensed) by the energy
supply company. This includes changes to the factory default parameters in the battery
inverter, which can be changed using the Webserver.
It must be ensured that the L1-L3 phases on the battery inverter's AC terminal and the
phases in the grid are assigned uniformly.
If residual current protection equipment (RCD) is used, a type A RCD ≥300 mA can be used
on the AC side. Use of a type A RCD is set in the Webserver. (Default setting: compatibility
with type A RCD).
POSSIBLE DAMAGE
Potential risk of damage when putting down the battery inverter. Always place the battery
inverter on its back after unpacking.
If the DC input is incorrectly wired, the battery inverter may be damaged. Check the
maximum wiring values before commissioning.
Installation
Perform battery inverter assembly, installation and commissioning based on the information
provided in the Installation chapter on page 56 onwards
Complete operating manual and warranty conditions
A detailed operating manual and further information about the battery inverter, such as information
about approved energy meters, battery storage units, country settings for commissioning and
approved countries in which the battery inverter can be operated, can be found online at
www.kostal-solar-electric.com > Download > PLENTICORE BI > Model > Country >
Operating manual
Information about the service and warranty conditions is provided in a separate document
available at
www.kostal-solar-electric.com > Download > PLENTICORE BI > Model > Country >
Warranty