D
BURNING OF THE HEATER
K
After you have ignited the heater, it will take 10 to 15 minutes before you can check
whether the heater is burning well. Too high a flame may cause smoke and soot,
whereas too low a flame causes smells. The page opposite the folding page shows
the minimum and maximum permissible burning heights of the flame (Fig. P). The
flame can be slightly adjusted with the knurled wick adjustment knob · (Fig. K).
Burning that is too low may be caused by:
insufficient fuel
poor fuel quality
insufficient ventilation
wastage of the wick
E

SWITCHING OFF THE HEATER

Let the heater burn at its lowest setting (Fig. K) for approximately one minute.
Then slowly turn the knurled wick adjustment knob · counter-clockwise to its
stop. The flame will extinguish after a little while.
In case of an emergency, switch off the heater by pushing in the safety button
³ (Fig. L).
F

ADJUSTING THE WICK HEIGHT

After a period of time the combustion may no longer be high enough (Section D). In
that case you can adjust the wick height to improve the flame. To do this, the heater
must have been switched off. Follow the procedure below:
L
Push the OFF button ³ (Fig. L).
1
Pull the knurled wick adjustment knob · off the heater, so the wick height
2
lock ¸ will be visible.
Take the plastic collar between your thumb and index finger and pull it out.
M
3
Turn the collar up one step, to either position 2 or 3 (Fig. M). Carefully push
the collar back, so the pin engages in the recess.
Carefully reinstall the knurled wick adjustment knob. This can be done in one
4
way only - check the rear of the cap for the correct position.
If adjustment of the wick height does not have the required effect, let the
heater burn until all fuel has been used up (Section H).
If the flame height is still too low and the wick is set on position 3, then contact your
dealer, or replace the wick, refer to section M. If the flame gets too high after adjus-
ting (Fig Q), the wick height lock should be placed one position lower again.
Otherwise smoke or soot may be caused.
(fill the tank)
(contact your dealer)
(put window or door ajar)
(contact your dealer or replace the wick,
refer to section M)