Planning
Outgoing air flow of the cleaned air:
If the air recirculation lies in the kitchen block and the cleaned air is returned through the base, a possibility should
be provided for the outgoing flow of air in the planning phase already.
The outgoing air flow can be guaranteed by a vertically shortened base or finned based. The outgoing air flow
opening should have a total area of at least 500 cm².
Note:
if the recirculation unit is installed in the vicinity of the base opening, there may be an increased exhaust speed in
this area. This can, however, be resolved by additionally attached components in the air circulation.
The product may only be connected by a certified electrician under consideration of the local regulations; the
same applies to the exhaust air connections.
The installer is responsible for perfect function at the installation site!
Only the Compair Flow 150 system of Naber recommended for air circulation and compatible with the cooktop
extractor fan may be used.
The nominal diameter of the recirculation ducts may not exceed 150 mm.
The following points absolutely must be observed in regard to air circulation:
-
Keep the air circulation paths as short as possible.
-
If possible, avoid sharp angles and lay the ducts in bends.
-
Never select a duct diameter smaller than 150 mm.
-
No bends/angles may be laid 50 cm in front of the fan component.
-
Always lay a straight piece of about 50 cm between two angles/bends.
-
During the installation, ensure that the recirculation unit is still accessible after completion of the kitchen
assembly. As such, it may be necessary to displace the base feet of the kitchen cupboards.
-
Ensure that there is sufficient space between the activated carbon components and adjacent compo-
nents. If this is not taken into account, this could lead to congestion in the exhaust air. This results in a
considerable reduction in the extraction performance of the entire cooktop extraction system.
-
During intended, private use there is no condensation formation due to the low frequency of use.
-
If the air recirculation unit is placed in an adjacent room, air return ducting must be provided for in the in-
stallation location of the vapour extraction apparatus. If this is not the case, the vapour extraction appa-
ratus must be assessed for exhaust air operation.
If the air return fails, please observe the information regarding exhaust air operation in the operating in-
structions of the cooktop extraction fan.