Download Print deze pagina

poolstar Poolex Mag Installatie- En Gebruikershandleiding pagina 106

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 139
4.6
Auto mode (Full Inverter)
Step 1 : Press
Step 2 : Press
Step 3 : Using buttons
EXAMPLE :
If the current temperature is 30°C, default setting temperature is 27° required temperature is 15°C.
4.7
Status values and advanced settings
The system's settings can be checked and adjusted via the remote control by following these
steps
Step 1 : Keep pressing
Step 2 : Press
Step 3 : Press
Parameters table
Paramètres
A
Inlet water temp.
b
Coil temp.
c
Ambient temp.
Inlet water temp. setting value (auto-
d
matic)
E
Inlet water temp. setting value (cooling)
Inlet water temp. setting value when
F
(heating)
G
Interval time of defrosting
H
Exit time of defrosting
Heat pump restart temp. di昀昀erence
L
Power o昀昀 protection
J
O
Ambient temp. of antifreeze protection
P
Coil temp. of entering defrosting
U
Coil temp. of exiting defrosting
20 |
EN
4. Use
to switch on your pump.
to switch from one mode to another until the auto mode is displayed.
and
select the required temperature.
1s until you enter the settings veri昀椀cation mode.
and
for see the parameters.
to select the setting to be viewed.
Indication
Commen-
Plage de réglage
taire
-19~99°C
-19~99°C
-19~99°C
8°C~40°C
30°C
8°C~28°C
12°C
10°C~40°C
27°C
10~80Min
40 Min
5~30Min
8 Min
1°C~10°C
2°C
0~1
1(Yes)
0°C~15°C
-5°C
-19°C~0°C
-3°C
1°C~30°C
20°C
Measured
Measured
Measured
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable

Advertenties

loading

Deze handleiding is ook geschikt voor:

Poolex mag3Poolex mag4Poolex mag5