Download Print deze pagina

First Steps; Horizontal Alignment - Futech MULTICROSS 3 Gebruiksaanwijzing

Advertenties

Beschikbare talen

Beschikbare talen

First steps

EN
Remove any protective lms where applied.
Insert the rechargeable batteries into the battery compartiment on the back of
the unit.
The batteries are fully charged by the charger.
Turn the transportation lock(3) to the "ON" position. The pendulum levelling
mechanism is released, and the instrument is able to align itself on its own. Make
sure that the instrument is not on too much of a slope (within 3°). If the slope of
the instrument should exceed 3°, the lasers will ash or will go out automatically.
Use the adjustable feet (6) or locate the tripod so that the air-bubble is within the
instrument's levelling range. NB: the accuracy of the instrument depends on the
proper centralisation of the air-bubble. Max. 2 mm/10 m.

Horizontal alignment

After disengagement of the pendulum locking system, and provided the
instrument is within its levelling range, the air-bubble is automatically at the
horizontal level.
The horizontal line may be activated or deactivated using the "H/V" button).
If possible, it is recommended that the horizontal line should be placed at
working height. This will improve the work quality.
NB: cross line lasers can only be used on tripods which are adjustable in height,
such as cranked or telescopic tripods.
Use the rotating case (4) to position the horizontal line.
If the workplace is very brightly lit, e.g. out of doors, it may be necessary to use
the laser receiver.
40
Multicross 3 Super
Multicross_3_SV_GREEN_New.indd 40
All manuals and user guides at all-guides.com
Vision-GREEN
www.laseto.be
11/06/13 16:59