Technical specifications
Power supply
Battery
Current draw
Operating temperature
Storage temperature with battery
Storage temperature without battery
Humidity
Temperature reading precision
Bus wire length and cross-sectional area
NOTE: TO AVOID INTERFERENCE PROBLEMS,
USE A SHIELDED CABLE OR TWISTED PAIR CABLE.
Insulation class
Protection rating
Dimensions
Frequency band used
Maximum power in the band
Wi-Fi channels
Product card (with ATAG zone bus system only)
Supplier name
Supplier identification model
Temperature control class
Energy efficiency contribution (%) for space heating
With an optional outdoor sensor or internet weather data:
Temperature control class
Energy efficiency contribution (%) for space heating
In a system with 3 zones and at least 2 room controllers:
Temperature control class
Energy efficiency contribution (%) for space heating
BUS
8 to 24V max; lithium ion battery
3.7 VDC
500 mAh
≤30mA
0 to 40°C
-10 to 45°C
-20 to 70°C
20% RH to 80% RH
+/- 0.5°C
max. 50 m
ø min. 0.6 mm²
III
IP 20
103mm x 103mm x 19.1mm
2400 MHz - 2483.5 MHz
+19 dBm - 802.11 b, g, n
1-13
ATAG
ATAG One zone
V
+3%
VI
+4%
VIII
+5%
EN / 19