ENGLISH
To prevent fire or shock hazard, do not expose this appliance to rain or moisture.
To avoid condensation to be formed inside, allow the unit to adapt to the surrounding temperatures when
bringing it into a warm room after transport. Condense sometimes prevents the unit from working at full
performance or may even cause damages.
This unit is for indoor use only.
Don't place metal objects or spill liquid inside the unit. Electric shock or malfunction may result. If a foreign
object enters the unit, immediately disconnect the mains power.
Locate the unit in a well ventilated spot, away from any flammable materials and/or liquids.
Don't cover any ventilation openings as this may result in overheating.
Prevent use in dusty environments and clean the unit regularly.
Keep the unit away from children.
Inexperienced persons should not operate this device.
Maximum save ambient temperature is 40°C. Don't use this unit at higher ambient temperatures.
The units' surface temperature may reach up to 85°C. Don't touch the housing with bare hands during its
operation.
Make sure to always place the unit on a stable surface, never install the fogger above the audience, a little
liquid can always drip from the fog output.
Allow the device about 10 minutes to cool down before you start servicing.
Always unplug the unit when it is not used for a longer time or before you start servicing.
Check that the available voltage is not higher than the one stated on the rear panel of the unit.
The power cord should always be in perfect condition. Switch the unit immediately off when the power cord
is squashed or damaged. It must be replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Never let the power-cord come into contact with other cables!
This unit must be earthed in order comply with safety regulations.
In order to prevent electric shock, do not open the cover.
Never repair a fuse or bypass the fuse holder. Always replace a damaged fuse with a fuse of the same
type and electrical specifications!
In the event of serious operating problems, stop using the fixture and contact your dealer immediately.
The housing must be replaced if they are visibly damaged.
Please use the original packing when the device is to be transported.
Due to safety reasons it is prohibited to make unauthorized modifications to the unit.
DESCRIPTION:
1. FOG FLUID CONTAINER: to be filled with CE-
certified smoke fluid. Make sure that the fog fluid
container is never empty during operation, this will
damage the pump of the fogger.
2. FLUID LEVEL INDICATOR: indicates how much fog
fluid is still available.
3. HANGING BRACKET: hanging bracket with two
knobs on both sides to fasten the unit + mounting
holes to fix a mounting hook.
4. NOZZLE: fog output. WARNING: HOT! Keep a
minimum distance of 1m.
5. REMOTE CONTROL INPUT: Used to connect the
supplied remote controller or the optional wireless
remote controller.
6. INPUT FUSE: When the fuse is blown, first locate
and solve the problem that caused the fuse to blow.
When the problem is solved, replace a damaged
fuse with a fuse of the same type and electrical
specifications.
7. MAINS CABLE: to be plugged in a mains wall
socket with earth connection.
®
JB SYSTEMS
2/24
OPERATION MANUAL
FX-700 FOGGER