22. Technical data

Operating voltage .......................... 2 x 1.5 V/DC battery, type AAA (alkaline)
Measurement range
Accuracy
.................................. ±2 mm
B)
Laser class ................................ 2
Laser wavelength ...................... 620 – 690 nm
Laser output power .................... <1 mW
Response time .......................... 0.3 seconds
Automatic turn-off time .............. 30 seconds (laser)
...................................................
Operating conditions .................. 0 to +40 °C, 10 – 80 % RH
Storage conditions ..................... -20 to +65 °C, 10 – 80 % RH
Dimensions (W x H x D) ............ 48 x 25 x 112 mm
Weight ....................................... 95 g
Measurement range and accuracy depend on how well the laser is
A)
reflected by the surface of the target object and from the brightness of
the laser point compared to the ambient light.
In favourable conditions, the accuracy for measurements <10 m is
B)
about ±2 mm. For measurements >10 m, calculate an influence of about
±0.1 mm/m.
In unfavourable conditions (i.e. bright sunlight or a poorly reflective
surface), the range is impaired and the result can deviate from the
correct result by up to 10 mm.
46
................ 0.05 – 30 m
A)
180 seconds (device)

Advertenties

loading

Deze handleiding is ook geschikt voor:

1007587