 The overload warning light may turn on for a few second if electrical equipment
is put into operation that requires a high peak current when starting. This is not
a malfunction.
C – DC 12 V Direct current application
Caution: Exclusively for charging 12 V batteries!
Instructions for charging an accumulator:
a) Put the Economy switch to the "OFF"
position.
b) Prepare the accumulator for
charging:
c) Disconnect the accumulator
terminals.
d) Remove all caps from the fluid filling
opening.
e) Add distilled water to the maximum
level (if required).
f) Measure the specific weight of the
accumulator fluid using an
acetometer and calculate the loading
time according to the table on the
right.
g) The specific weight for fully charging
the accumulator should be 1.26 to
1.28. It is recommended that this be
checked every hour.
h) Using the accumulator cables,
connect the poles of the accumulator
to the equivalent poles of the DC
direct current power point of the generator: + on + and - on - !
i) Check that all cables have been connected correctly and press the DC direct
current protection to the "ON" position.
3 – Stopping the engine
e) Switch all connected equipment off and remove the plug(s) from the power point
on the generator.
f) Put the engine switch to the "STOP" position.
g) Close the fuel cock, putting it in the " OFF" position.
h) Turn the venting button on the tank cap to the closed position
(counterclockwise).

Special conditions

The maximum capacity of the generator is calculated under normal operating
conditions. If the generator is used under special conditions, for example:
Use at a great height;
-
38