Unit Water and 2 posheater water cool.
11 Bedradingsschema
toestel met waterwisselaar en tweede externe waterwisselaar voor waterkoeling
56 55 54 53 52 51 50
56 55 54 53 52 51 50
49
49
GND
GND
GND
GND
GND
GND
GND
GND
Room Int2
Room Int2
Int1
Int1
Ext3
Ext3
FLAP
FLAP
RUN
RUN
ALARM HEAT
ALARM HEAT
IN-1 IN-2
IN-1 IN-2
L
L
L
L
LF1 LF2
LF1 LF2
1 2 3 4 5 6
1 2 3 4 5 6
7 8
7 8
Unit Water
N
L
Water pump
for coil #2
L N
230V
toestel met waterwisselaar en tweede externe elektrische wisselaar
56 55 54 53 52 51 50
56 55 54 53 52 51 50
GND
GND
GND
GND
GND
GND
GND
GND
Room Int2
Room Int2
Int1
Int1
Ext3
Ext3
FLAP
FLAP
ALARM HEAT
ALARM HEAT
L
L
L
L
LF1 LF2
LF1 LF2
IN-1 IN-2
IN-1 IN-2
1 2 3 4 5 6
1 2 3 4 5 6
7 8
7 8
34
ver.3 29-04-20
W
KOEL
48
48
47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
GND
GND
GND
GND
GND
GND
0-10
0-10
PWM
PWM
GND
GND
RPM
RPM
RPM
RPM
NOT USED
NOT USED
Ext2
Ext2
Ext1
Ext1
CO2
CO2
Fan In
Fan In
Fan Out
Fan Out
CONTROL PANEL
AC5-M
AC5-M
SSR
SSR
SSR
SSR
FIRE
FIRE
PREHEAT
PREHEAT
ERR.
ERR.
BOOST /PIR
BOOST /PIR
EXT
EXT
POST
POST
PREH
PREH
W.PUMP
W.PUMP
+
+
+
+
GND
GND
GND
GND
9
9
10
10
11
11
12
12
13 14 15 16 17 18 19 20 21 22 23 24
13 14 15 16 17 18 19 20 21 22 23 24
24V GND GND
E
49
49
48
48
47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
GND
GND
GND
GND
GND
GND
PWM
PWM
GND
GND
RPM
RPM
RPM
RPM
0-10
0-10
Ext2
Ext2
Ext1
Ext1
CO2
CO2
Fan In
Fan In
NOT USED
NOT USED
Fan Out
Fan Out
CONTROL PANEL
AC5-M
AC5-M
SSR
SSR
SSR
SSR
FIRE
FIRE
PREHEAT
PREHEAT
BOOST /PIR
BOOST /PIR
RUN
RUN
ERR.
ERR.
EXT
EXT
W.PUMP
W.PUMP
POST
POST
PREH
PREH
+
+
+
+
GND
GND
GND
GND
9
9
10
10
11
11
12
12
13 14 15 16 17 18 19 20 21 22 23 24
13 14 15 16 17 18 19 20 21 22 23 24
24V GND GND
2VV. Creating innovative solutions for you and your business since 1995.
JTAG
JTAG
32 31
32 31
50 49 48 47 46 45
50 49 48 47 46 45
GND
GND
PWM
PWM
GND
GND
PE
PE
GND
+12
B
A
CANL
CANL
CANH
CANH
WAT
WAT
GND
GND
BYPP
BYPP
PUMP
PUMP
0-10
0-10
GND
GND
+12V
+12V
INT
INT
OUT
OUT
1 2
1 2
B
B
I-BUS
I-BUS
A
A
OUTPUT
OUTPUT
N
L
Water pump
for coil #1
L N
230V
JTAG
JTAG
32 31
32 31
50 49 48 47 46 45
50 49 48 47 46 45
GND
GND
PWM
PWM
GND
GND
PE
PE
GND
+12
B
A
CANL
CANL
CANH
CANH
WAT
WAT
GND
GND
BYPP
BYPP
PUMP
PUMP
GND
GND
+12V
+12V
INT
INT
OUT
OUT
0-10
0-10
1 2
1 2
B
B
I-BUS
I-BUS
A
A
OUTPUT
OUTPUT
N
L
Water pump
for coil #1
L N
W.PUMP
230V
Postheater
5
3
2
1
JTAG
JTAG
44
44
43
43
42 41 40 39 38 37 36 35 34
42 41 40 39 38 37 36 35 34
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
10V
10V
GND
GND
WAT
WAT
WAT
WAT
EXT4
EXT4
INT0
INT0
-IN
-IN
-OUT
-OUT
NOT USED
NOT USED
NOT USED
NOT USED
HEAT
HEAT
ADB
ADB
COOL
COOL
ADB
ADB
HEATPUMP
HEATPUMP
CONDEN-
CONDEN-
PIR
PIR
PUMP
PUMP
/HEAT
/HEAT
ERROR
ERROR
SATE
SATE
ON/OFF
ON/OFF
ERROR
ERROR
DEFROST
DEFROST
3 4
3 4
5 6
5 6
7 8
7 8
9
9
10
10
11
11
12 13 14 15 16 17 18
12 13 14 15 16 17 18
Coil 2 ELECTRIC
L
230V
N
44
44
43
43
42 41 40 39 38 37 36 35 34
42 41 40 39 38 37 36 35 34
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
10V
10V
GND
GND
WAT
WAT
WAT
WAT
EXT4
EXT4
INT0
INT0
-IN
-IN
-OUT
-OUT
NOT USED
NOT USED
NOT USED
NOT USED
HEAT
HEAT
ADB
ADB
COOL
COOL
ADB
ADB
HEATPUMP
HEATPUMP
CONDEN-
CONDEN-
PIR
PIR
PUMP
PUMP
/HEAT
/HEAT
ERROR
ERROR
ON/OFF
ON/OFF
ERROR
ERROR
DEFROST
DEFROST
SATE
SATE
3 4
3 4
5 6
5 6
7 8
7 8
9
9
10
10
11
11
12 13 14 15 16 17 18
12 13 14 15 16 17 18
El. mixing valve
for coil #2
I-BUS
I-BUS
I-BUS
I-BUS
INPUT
INPUT
OUTPUT
OUTPUT
B
B
A
A
+12V
+12V
GND
GND
B
B
A
A
+12V
+12V
GND
GND
POSTHEAT 2
230V
EOKO2
0-10V
I-BUS
I-BUS
I-BUS
I-BUS
JTAG
JTAG
INPUT
INPUT
OUTPUT
OUTPUT
B
B
A
A
+12V
+12V
GND
GND
B
B
A
A
+12V
+12V
GND
GND