Remove the transparent vinyl cover at the bottom of the motion sensor (img. 1).
Loosen the screws in the connection terminal. Connect the power to connection terminal of the
2
motion sensor according to the connection diagram (img. 2)(img. 3).
3
Reinstall the vinyl cover. Fold the metal spring of the motion sensor upwards. Insert the motion
sensor into the hole or installation box. Once Released, the springs will fix the motion sensor in
place (img. 4)(img. 5).
4
Turn the LUX knob clockwise to the maximum setting (sun). Turn the TIME knob anti-clockwise
to the minimum setting (10s) (img. 6).
5
Turn on the power. After a warm-up time of 30 seconds, the motion sensor will start operation.
When the sensor receives the induction signal, the connected lamp will turn on. If the motion
sensor receives no further induction signal, the load stops working within 10 seconds (±3
seconds) and the connected lamp will turn off.
6
Turn the LUX knob anti-clockwise to the minimum setting (3). If the ambient light is more than
3LUX, the motion sensor will not activate and the connected lamp will not turn on. If the ambient
light is less than 3LUX, the motion sensor will activate. If no induction signal is present, the
motion sensor will deactivate within 10 seconds (±3 seconds) (img. 6).
MANUAL OVERRIDE FUNCTION
1. Sensor mode: Stay on
Now switch wall switch OFF-ON, OFF-ON twice within 3seconds. The sensor will now hold your light
ON continuously just likes a normal light.
2. Stay on: Sensor mode(The following either method is ok)
1). Switch your wall switch OFF, then switch ON after 0.3seconds.
2). If the light left ON (not change the sensor to sensor mode by hand), the sensor itself will also auto-
matically return to the sensor mode after 8hours.

TECHNICAL SPECIFICATION

DETECTION RANGE: 360°
VOLTAGE: 220-240V/AC
FREQUENCY: 50/60Hz
RATED LOAD: 1200W (Incandescent lamp)
600W (Energy-saving lamp & LED lamp)
DETECTION DISTANCE: max. 8m (<24°)
TIME DELAY: 10sec ± 3sec to 15min ± 2min (adjustable)
AMBIENT LIGHT: <3-2000LUX (adjustable)
INSTALLATION HEIGHT: 2.2-4m