Download Inhoudsopgave Inhoud Print deze pagina
Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

INSTALLATION MANUAL
1
Loosen the screw on the bottom and unload the bottom (img.1).
Pass the power wire through the hole with gasket in the bottom. Connect the power wire into
2
connection-wire column according to the connection-wire diagram. Fix the bottom on the
selected position with the inflated screw (img.2).
3
Fix the bottom with inflated screw on the selected position (img.1.)
4
Install back the sensor on the bottom, tighten the screw and then test it.
5
It not only can be installed on the wall directly but also can be installed on the Ceiling.
6
Turn the LUX knob clockwise on the maximum (sun). Turn the TIME knob anti-clockwise on the
minimum (10s) (img.3.)
7
Switch on the power; the sensor and its connected lamp will have no signal at the beginning.
After Warm-up 30sec, the sensor can start work. If the sensor receives the induction signal,
the lamp will turn on. While there is no another induction signal any more, the load should stop
working within 10sec±3sec and the lamp would turn off.
8
Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is more than 3LUX, the
sensor would not work and the lamp stop working too. If the ambient light is less than 3LUX
(darkness), the sensor would work. Under no induction signal condition, the sensor should stop
working within 10sec±3sec.
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise the sensor
lamp could not work!

TECHNICAL SPECIFICATION

DETECTION RANGE: 180°/360°
VOLTAGE: 220-240V/AC
FREQUENCY: 50/60Hz
RATED LOAD: 1200W (Incandescent lamp)
600W (Energy-saving lamp & LED lamp)
DETECTION DISTANCE: max. 12m (<24°)
TIME DELAY: 10sec±3sec to 15min±2min (adjustable)
AMBIENT LIGHT: <3-2000LUX (adjustable)
INSTALLATION HEIGHT: 1.8-2.5m