Open the air inlet grill, pul the air filter from the inlet grill.
Wash the air filter by immersiin it gently into warm water to wash out accumulated
dust and lint. IF the filter is very dirty, add mild household detergent in the water.
Let the filter dry thoroughly.
Place the filter back in the air inlet grill. Place the grill back in the unit.
Note :
Turn off the unit and unplug before cleaning.
If the air filter is blocked, the airflow volume will decrease. We suggest cleaning the
filter once very two weeks or more ofeh if necessary.
Let the filter dry thoroughly before reinstalling it.
HOW TO DRAIN THE CONDENSE WATER
When the unit is running at cool mode, condense water will drain into the water tank.
Buzzer will sound when the water tank is full and error code „E4" will display on the
LCD. At the same time cooling sytem stops running automatically and the fan will
stop after 3 minutes.
Draining the water tank
Place the drainage box under the drainage hole
Disconnect he stopple drainpipe, then the condensed water will automatically flow
out.
When the drainage box gets full, push the stopple drainpipe back into the drainage
hoe, and empty the drainage box.
Repeat above steps unitl the water tank is empty.
Continuous drainage
This product has a continuous drainage funcion. If you use this unit frequently, please
connect the pipe to the unit properly so that the unit can drain the water successfully.
Disconnect the stopple drainpipe, and store it for later use.
Connect supplied drainage pipe to the drainage hoel, condensed water will flow out
automatically.