26
Installation
– expired term is not due.
If one or more defects are visible, do not repair the pipe, but replace it.
When installation is complete, make sure that the seal of each pipe fitting is correct. Use a
soapy solution, not a flame!
Injectors replacement
1. Remove the pan supports.
2. Remove the caps and crowns of the burner.
3. With a socket spanner 7 remove the injectors and replace them with the ones which
are necessary for the type of gas you use (see table in Technical Data section).
4. Assemble the parts, follow the same procedure backwards.
5. Replace the rating label (it is near the gas supply pipe) with the one for the new type of
gas supply. You can find this label in the package of the injectors supplied with the ap-
pliance.
If the supply gas pressure is changeable or different from the necessary pressure, you must
fit an applicable pressure adjuster on the gas supply pipe.
Adjustment of minimum level
To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum position.
3. Remove the control knob.
4. With a thin screwdriver, adjust the bypass screw position. If you change from natural
gas to liquid gas, fully tighten the adjustment screw in. If you change from liquid gas to
natural gas, undo the by-pass screw approximately 1/4 of a turn (1/2 of a turn for Triple
Crown burner).
1
Minimum adjustment screw
5. Make sure the flame does not go out when you quickly turn the knob from the maxi-
mum position to the minimum position.
Electrical connection
• Ground the appliance according to safety precautions.
• Make sure that the rated voltage and type of power on the rating plate agree with the
voltage and the power of the local power supply.
1