prog.
SAX
L
Figure 4.
• Place the wall socket back in the junction box and screw it in place.
MBO 1991284G01 002
Mounting / installation (continued)
Always switch on the power before programming.
!
Avoid the contact with life parts!
Programming modeg
Activating programming mode
The dimming actuator needs to be put into programming mode
before it can be programmed:
• Press the program button for at least three seconds, see
Figure 6; the red LED will light up permanently.
!
Note
If no setting command is received within 60 seconds the
module will automatically exit programming mode.
Cancelling programming mode
• Briefly press the program button once, or wait 60 seconds, so
that programming mode is cancelled automatically.
Programming the options
Table 1 includes the standard settings and options.
The dimming actuator is set to "Standard".
26 MBO 1991284G01 002
Mounting / installation (continued)
1
PROG.
DAX
10
N
L
3.3 mm
2
PRO G.
N
Figure 5.
• Remove the membrane from the fuse link (1).
• Replace the fuse link using pointed pliers (2).
23
24 MBO 1991284G01 002
PROG.
DAX
10
N
L
Proceed as follows to access the options:
• Put the module into programming mode.
• Send the desired command in "Setup Command" twice, via
the PUX programming unit or the Xanura Home Control Box.
• The program LED confirms the "Setup Command" by flashing
a specific number of times.
• Cancel programming mode.
Testing and replacing the dimactuator fuse
Testing the dimactuator fuse (type TR5-1, 6 AT). Disconnect the
dimactuator from the load (lamp, transformer). Next, measure the
output with a voltage probe. If no voltage is detected, the fuse is
faulty.
!
Please note, if the fuse has blown, the programming
LED will still flash.
Replacing a faulty fuse on the DAX10
It is possible to replace the fuse without opening the module (if
the module is opened, the warranty will be null and void).
Remove the film over the fuse and pull the fuse carefully out of
the module using a pair of long snipe nose pliers. Replace the
fuse with one of the following types of fuse (if any other type of
fuse is used, the warranty will be null and void):
Supplier
Description
dimmer fuse
Littelfuse
LT-5 ALg
Bussman
ETF Radial Lead Micro Fuse
ELU
Sub miniature fuse links
Wickmann
Subminiatur fuse No 372.TR5
Bel fuse
Time Lag Radial Lead Micro Fuse
List of permitted dimactuator fuses for the Xanura DAX10 and DAIX10 module.
Mounting / installation (continued)
Table 1
Standard
Address A1
No All Lights On
No All Lights Off
No All Units Off
!
Note
• When in programming mode, always enter the address
first and then the other settings.
Figure 6.
• When a new address is received the optional commands
Activating and
are lost (reset).
cancelling
programming mode.
Electronic dimmers, like the DAIX10 and DAX10,
!
are using the sinus on the power line to
determine the power that will be transformed. In
an unstable power network, or as result of a
short duration of low frequent pulses, the shape
of the sinus can be disturbed which might result
in some temporary fluctuations of light.
MBO 1991284G01 002
27
28 MBO 1991284G01 002
Order number
supplier
0663.01.6
BK ETF1.6
166050-1,6AT
372-1160-041
MTR1,6 short leads
MBO 1991284G01 002
25
Optional
Setup
Number
Command
flashing
A2...P16
Address
2
All Lights On
All Lights On
6
All Lights Off
All Lights Off
10
All Units Off
All Units Off
8

Advertenties