Wiring diagram
L wire
(Phase wire, often brown)
N wire
(Neutral wire, often blue)
LED
LOAD
(Switching wire, often black)
DIMMER
Single-pole switching
L wire
N wire
LED
LOAD
Setting min. light level
Turn on the lights using the dimmer shaft. Then turn the dimmer shaft as far as possible
to the left (minimum light output). If the lights blink, use a screwdriver to turn the MIN
potentiometer slowly to the right for stable light. Is the light already stable? Then slowly turn
the MIN to the left for even better dimmability, until just before the point where the lamps
start flashing. That is the best dimmability of these LED lamps.
Reduction of connection capacity by PowerFactor
When calculating the LED connection power of the dimmer, take into account the PowerFactor
of the dimmable LED lighting. See the global calculation below for this.
NUMBER OF LED LIGHT
=
NOMINAL POWER
SOURCES
Example: 10 lamps * (5W per lamp / 0.8 PowerFactor) = 62.5 Watt
Loop-through possible to
adjacent socket/switch.
Two-way switching
L wire
N wire
LED
LOAD
NOMINAL POWER LED /
*
POWERFACTOR.
EN
Manual
ECO-DIM.01
Led dimmer phase-on and phase-off (R,L,C)
Note:
•
This is a two-wire dimmer and it should be connected as shown under the heading
'Wiring diagram' .
•
Installation of the dimmer on a 230V mains should be carried out by a qualified
professional, taking into account national regulations. Ensure that the electricity is
switched off during all work.
•
You cannot connect more than one dimmer in parallel. To then control the same load
from two points.
•
Dimmer is not suitable for wound/magnetic or core transformers.
Dr. Huber Noodtstraat 89
7001 DV, Doetinchem, Netherlands
(Imported by NJ Trading B. V .)
EcoDim B.V.