error code and trouBle sHootInG
Display code
Drinking water thermoprobe failure
Erd
Heating thermoprobe failure
ErH
inflowing failure (the water fill in more than 45
Er 1
minutes)
Heating Failure
Er2
water leakage
Ell
the timing
if there are some circuit failure appear in the timer,
indicator flashing
the timing function would be invalid
electrIcal scHematIc dIaGram
688120 nl-en ma 2016
Failure
Solution
to check if its connection is loosen
to clean up the scail attach on it and
check if its connection is loosen
to check whether the water resource is
under normal supply.
to check the magnetic value.
replace the heating element
to check whether the water resource is
under normal supply.
to check the magnetic value, replace it if
needed.
to check whether the connection of every
thermoprobes is fixed.
to replace a new display board or circuit
board.
17