EN
Cifero XT Keypad
Technical data
Power supply
12-24V AC/DC +/- 20%
Standby current consumption (DC)
20mA DC
Standby current consumption (AC)
80mA AC
Max. current consumption (DC)
< 90mA
Max. current consumption (AC)
< 250mA
Max. Switching capacity relay
24V AC/DC, 8A
! Do not connect an inductive load (ex. magnet, coil, lock, ..) !
Memory
60 codes (4- tot 8-digits)
microSD cardreader
micro SDHC card, FAT32, max. 16GB
Temperature range
-25°C .. +50°C
Protection degree keypad KP10
IP55
Protection degree controller SD60
IP20
Dimensions keypad KP10
46 x 130 x 27 mm
Dimensions controller SD60
91 x 79 x 32 mm
Heating*
5W
*only available in combination with MW30-12ST power supply
Functional description
Controller for use with an ENTRYA Cifero KP10 keypad. The controller will verify the code
that is entered on the keypad with the saved codes. When there is a match, the relay is
activated.
Safety instructions
•
These installation and operating instructions must be read and fully understood bij the
persons operating or servicing the device. All instructions must be fully adhered to.
•
Use only original spare parts and accessories approved by the manufacturer.
•
If the keypad is used for the control of a unit where there is a risk to persons, the
operator must at all times be able to see the unit during operation.
•
The kyepad may only be used, if all movements of the door can be supervised by the
operator and are not obstructed.
•
Do not install the keypad within the opening range of the door.
•
Install remote control in a location that allows for an unobstructed view of the
controlled unit.
•
Do not use hose or high pressure cleaner for cleaning the keypad. Water can
penetrate the device and damage or destroy it.
Warranty
The Entrya Cifero keypad sold from July 2014 is subject to a five-year warranty against
manufacturing defects. Normal wear and tear, such as discoloration by sunlight, is not
covered by warranty.
The warranty complies with statutory requirements. Your local dealer should be contacted in
connection with any warranty-related matters. Your warranty entitlements only apply to the
country in which the keypad was purchased.
If you require after-sales service, spare parts or accessories, please contact your dealer.
Disposal
This product consists of several components which in turn could contain
contaminants. Do not let them pollute the environment! Enquire information about
recycling and disposal systems for this product and always comply with the relevant
statutory regulations.
EC Declaration of conformity
See website: www.entrya.eu
Mounting
Install the keypad KP10 and controller SD60 on a level surface free from vibrations and use
appropriate fasteners. Mount the controller SD60 in a dry, enclosed space so that it is not
accessible to unauthorized persons and children.
The keypad is connected via the supplied cable. Use a single cable and do not install over a
large distance in parallel with other wiring.
max. length without heating installed:
200m (0.22 mm²)
max. length with heating installed:
5m (0.22 mm²)
10m (0.5 mm²)
15m (0.75 mm²)
0V
12-24V
NO
2
C
NC
3
4
0V
5
6
H
+
7
8
0V (black)
+K (red)
9
0
DATA (white)
OPEN-LED
DIP-switch
DATA-LED
Description Cifero SD60 Controller
POWER-LED
ON if power supply is connected
PROG-button
Button to program codes
OPEN-button
Activates relay during configured timing.
DATA-LED
ON when controller and keypad communicate.
PROG-LED
ON when controller is in programming mode
DIP-switch
Determines the switching time of the relay
DIP1
DIP2
Time
ON
ON
0.5
OFF
ON
5
ON
OFF
10
OFF
OFF
Toggle (3)
(3) The status of the toggle function is stored in the controller.
If the controller reboots the status of the relay is retained.
0V
Ground (-)
12-24V
12 - 24V AC/DC
NO
Normally Open Contact
C
Common Contact
NC
Normally Closed Contact
Heating (option)
0V
MW30-12ST voeding (V-)
+H
MW30-12ST voeding (V+)
Description Cifero KP10 keypad
LED button 1
LED from button 1 and the buzzer are ON when the relay is
and buzzer
active or when the controller is in programming mode.
Lighting
The buttons are continously on. The lighting is dimmed briefly
when a key is pushed.
Connect additional keypad
Connect red, black and white wires from both keypads with eachother.
The keypad KP10 is equipped with a connector for connecting the cable.
Making it easy to replace the keypad or separate parts.
POWER-LED
PROG-button
The keypad functions without the red wire connected.
However, it is encouraged to connect the red wire for the best interaction
between user and keypad. When not connected, the buzzer, lighting and
heating cannot work, also it will be impossible to add an extra keypad.
P
P
P P
P P
P P
P
P
P P
P
P
P
P
P
P
P P
P
P
P
MW30-12ST power supply for heating
The MW30-12ST will supply the heating for the KP10 keypad. This heating will only be active
when the temperature drops below 0°C. The intensity of the heating is dependent from the
PROG-LED
outdoor temperature.
Heating the keypad decreases the risk of wet keys that get frozen and guarantees a flexible
membrane behind the keys during extreme cold temperatures.
It is not allowed to use another power supply then the MW30-12ST. Any other
power supply could result in a defect device. A defect caused by using a faulty
power supply will not be covered by warranty.
Connect the terminals 12-24V and +H and do not connect another power
supply!
OPEN-button
microSD-cardreader
Start Up
Connect the terminals and power supply. The POWER-LED will be ON and the buzzer will
beep briefly. The keypad is, after approximately 10s, ready for use.
Programming codes via the keypad
•
The length of the code is at least 4 and at most 8 digits.
•
The first programmed code will become the Mastercode.
•
The Mastercode also activates the relay.
•
The length of the Mastercode defines the length of all other codes.
•
Programming codes will automatically erase the memory of the
controller.
1.
Press the PROG-button and keep pressed. After 4s the PROG-LED will blink once, after
another 6s the PROG-LED will blink again. Release the PROG-button, after 5s key 1 on
the keypad and the buzzer will be activated.
* Programming mode will be automatically closed, without erasing the memory, after
30s of inactivity.
* If the controller is inaccessible, the programming can be started from the keypad.
Press the Mastercode and keep the last key pressed until the buzzer is ON. Release
the key, after 5s key 1 on the keypad and the buzzer will be activated.
2.
Press the Mastercode (first code) and wait for confirmation, key 1 dimmes 3x times
and the buzzer gives 3x beeps.
3.
Start within 6s with programming the next code. This code has to have the same
amount of digits as the Mastercode.
4.
Repeat step 3 up to 60 codes.
5.
Wait 6s after programming your last code, the controller will exit the programming
mode.
Programming codes of making a backup with an SD-card
Programming codes via microSD-card is advised when there is a large amount of codes to
be controlled. Please read the manual: Cifero Code Manager.
Normal usage
Press a valid code. If the code is valid, key 1 and the buzzer will be ON. The relay will
simultaneously be activated. If the code is invalid, restart your try.
The keypad is blocked for 20s if an invalid code has been entered 6x times in a row. During
these 20s, key 1 will be blinking and the buzzer will be ON.
After 20s the normal behaviour will be resumed, press a valid code.
12-24V
0V
H
+
MW30-12ST
-
230V AC
+
Power Supply