Installatie handleiding:
The RONDO sealing collar is supplied ready-to-install with
two stainless steel clamping straps for fixing.
Choose the correct size of RONDO Protect sealing collar
corresponding to the outer diameterof the medium pipe to
be waterproofed.
Soiled pipe walls must be cleaned prior to installing the
RONDO sealing collar.
Soaking in warm water (approx. 10 minutes) makes the
sealing collar even easier to install, espacially at low
temperatures.
The RONDO sealing collar is pulled on from the spigot
end before the pipe is installed.
The RONDO sealing collar should be mounted centrally on
the wall/floor plate.
The minimum concrete cover of 5 cm must not be
undercut.
The distance to the surrounding reinforcement or other
components must be at least 3 cm.