WWW.HEATSTRIP.EU Retselseweg 6 | 5473 HC | Heeswijk-Dinther ENGLISH Assembly instructions Operating Instructions NEDERLANDS Gebruiksaanwijzing 10~13 14~17 0086 2017.V1 PIN No.51CS4797...
Pagina 2
ENGLISH Technical data for TGH34WL / TGH34WN Product Name Radiant Gas Heater Model Type Wall Mounted Model TGH34WL TGH34WN Input 9.4KW (G30:684g/h, G31:672g/h) Gas Category I3B/P(30) I3B/P (50) I3+(28-30/37) Gas and G30 Butane at 28-30 mbar G30 Butane and G31...
Parts List No. DESCRIPTION PART NO. QTY. Protective Guard P03351021D Name Plate P00408001A Heat Deflector P03351034D Burner Assembly P02005035D Burner Holder P020110804 Manifold assembly (NG20) Y0060864 Manifold assembly (LP30) Y0060862 Manifold assembly (LP50) Y0060863 Gas valve Black string P03351035A Red string P03351036A Gas Valve Bracket 1 P03351037A...
Pagina 5
ENGLISH ASSEMBLY 1. Install Heat Deflector Pan Head Screw M5x10mm Qty. 3 Part # S112M05102 2. Install Wall Mounting Bracket Install the wall mounting bracket to the wall with appropriate fixings for the material to be attached (Masonry, wood, metal etc.), using 6 appropriate fasteners(not included), then tighten all the screws securely.
GAS (LPG) TANK INFORMATION STORAGE (after use) Connecting gas circuit to LPG cylinder • Turn OFF the appliance. • Keep at hand suitable crossed screwdriver, adjustable spanners, pliers and wrenches. Before assembly, make • Disconnect LPG cylinder. sure all protection packing material has been removed. •...
ENGLISH GENERAL WARNINGS WARNINGS INFORMATION FOR OUTDOOR USE ONLY - For your safety • Do not modify the appliance. • Do not move the appliance during use. • Gloves are recommended to be used while • If the information in this manual is not followed •...
ENGLISH GENERAL WARNINGS GAS (LPG) WARNINGS • Do NOT use this gas heater if any part has • The pressure regulator is set for 30-50mbar. • LP gas is flammable and hazardous if handled been under water. Immediately call a qualified improperly.
Pagina 9
ENGLISH Heater Lighting Instructions Check for Gas Leaks Connecting gas circuit to NG source Never test for leaks with an open flame. Prior to first • Protect appliance from wind during lighting and operation. • Keep at hand suitable crossed screwdriver, adjustable use, at the beginning of each season, or every time spanners, pliers and wrenches.
Flame is yellow (c) Check venturi for dust Clean if necessary (d) Check burner ports for blockage Clean if necessary If you can not solve trouble according to one of the mentioned solution, heatstrip@heatstrip.eu or contact your dealer or Distributor Responsible.
NEDERLANDS • Kinderen en volwassenen moeten worden ge- ALGEMENE WAARSCHUWINGEN WAARSCHUWINGSINFORMATIE waarschuwd voor de gevaren van hoge opper- UITSLUITEND VOOR GEBRUIK BUITENSHU- vlaktetemperaturen en op een veilige afstand • Pas het toestel niet aan. IS - voor uw veiligheid worden gehouden, terwijl de kachel in gebruik •...
NEDERLANDS • De drukregelaar is voor 30-50 mbar ingesteld. ALGEMENE WAARSCHUWINGEN-VERVOLG GASWAARSCHUWINGEN (PROPAAN) • De uitlaatdruk van de regelaar is 30~50 mbar • Gebruik de gaskachel NIET als een onder water • Propaangas is brandbaar en gevaarlijk wan- afhankelijk van het land van gebruik. heeft gestaan.
Pagina 13
NEDERLANDS Het gascircuit aansluiten op de aardgasbron Ontstekingsinstructies van de kachel Controleren op gaslekken • Houd een geschikte kruisschroevendraaier, verstelbare • Scherm het toestel af tegen wind tijdens het Test nooit op lekkage met een open vlam. Vooraf- sleutels, tangen en moersleutels bij de hand. Vóór het aansteken en gebruik.
(c) Controleer de venturi op stof Reinig indien nodig (d) Controleer de branderopeningen op ver- Reinig indien nodig stopping Als u het probleem niet kan oplossen volgens één van de genoemde oplossingen, heatstrip@heatstrip.eu contact op met uw dealer of verantwoordelijke distributeur.