Download Inhoudsopgave Inhoud Print deze pagina

Burner And Nozzle Specifications - Indesit THP 641 W/IX/I NL Gebruiksaanwijzing

Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

Burner and nozzle specifications

GB
Table 1
TYPE OF GAS
USED
NATURAL GAS
(Methane)
G25
LIQUEFIED
PETROLEUM GAS
(Butane)
G30
LIQUEFIED
PETROLEUM GAS
(Propane)
G31
Type of gas used
G25 25 mbar
G30 30 mbar
G31 30 mbar
ELECTRIC SUPPLY: 220-240V~ 50/60Hz 0,6W
S
MW
S
THP 641 W/IX/I NL
641 THP W/IX/I NL
8
TYPE OF
NOZZLE
BURNER
THERMAL
FLOW RATE
Semi-Rapid
94Y
Auxiliary
F1 72
MW
141A
63
Semi-Rapid
50
Auxiliary
MW
91
Semi-Rapid
63
Auxiliary
50
MW
91
Model configuration
4 BURNERS
1MW - 2S -1A
1MW - 2S -1A
1MW - 2S -1A
A
RATED
RATED
CONSUMPTION
kW
1.65
183 l/h
1.00
111 l/h
3.50
388 l/h
1.65
120 g/h
1.00
73 g/h
254 g/h
3.50
1.65
118 g/h
1.00
71 g/h
3.50
250 g/h
Rated thermal
ow rate (kW)
consumption
7.80
7.80
7.80
CATEGORY II2L3B/P
REDUCED
GAS PRESSURE
HEAT
CAPACITY
kW
min.
0.40
0.40
20
1.65
0.40
0.40
25
1.65
0.40
0.40
25
1.65
Total rated
Air required (m³) for
burning 1 m³ of gas
864 l/h
8.187
567 g/h
30.94
557 g/h
30.94
mbar
rat.
max.
25
30
30
35
30
35

Advertenties

Inhoudsopgave
loading

Inhoudsopgave