Sensor
installation.
1. Setup.
• Install the sensor at the desired water level.
• Connect the sensor to the power supply and the pump.
• Plug in the power supply and the device will automatically maintain the
water level.
Important while using
• Protective cover must be installed!
• The water outlet should not be aligned with the sensor!
• Anti-siphon prevention, if you stop the pump there is the risk of siphoning through the hose, make sure the hose is
above the maximum water level in both the sump/tank as well as in the reservoir at all times. You can also make a small
hole in the hose as an extra protection.
2. Testing.
To test correct operation, lift the sensor just a bit out of the water until the green led turns off. Now the system will
automatically add water. Don't forget to put the sensor back in the correct place.
3.
Alarm and
resetting.
• In the case of operational errors, such as water shortage in the water reservoir or if the water level can't be maintained,
the pump will stop after several attempts and alarm with a red flashing light.
• To stop the alarm, unplug power supply, wait for 10 sec, re-plug and the device will resume normal operation.
• Reset the system if you change the configuration of your installation, unplug power and re-start the setup
process from step 1!
Maintenance.
• Scale and salt settlement may influence proper functioning, regular cleaning is needed to ensure
proper operation!
• Disconnect power supply and pump from mains before any maintenance on the aquarium.
• Open and remove rotor and axle, to clean them.
• Clean sensors, impeller and shaft with 50% vinegar and 50% water solution. Let them soak for a
minimum of 15 minutes.
• Reassemble shaft and impeller. Verify that shaft caps are properly installed.
• Reassemble pump and place back in aquarium.
• The pump is a wearing part that depending on usage will need changing yearly, this is
considered normal maintenance and not covered under warranty.
• Replacement pumps, sensors and power supply are available at your dealer.
(pic 01)
(pic 02)
(pic 03)
(pic 01)
(pic 02)
Siphon hole
GB
(pic 03)
Blue
Marine.
3