38
CONNECTING THE HOB TO THE ELECTRICAL SYSTEM
• The hob is supplied with a connection cable, but without a plug and, in accordance with connection diagram
A1, it is set by default for 2 x 1 phase (230VDC). The hob uses a so-called 5-pole Perilex plug (not included). In
the meter cupboard, the groups must each be protected with a 16 Ampere fuse at least.
• The hob can also be connected in accordance with connection diagram A2 or A3. This may only be performed
by a certified installer.
• The socket for connecting to the electrical system must be provided with an earthing pen and may not be
located above the hob. The socket for connecting to the electrical system must also be accessible for the user
after placement of the hob.
• Before connecting the hob, check that:
- the fuse and electrical system are suitable for the load of the hob,
- the electrical system is equipped with an efficient earthing system that meets the current standards
and regulations.
- the socket is easily accessible.
connection block
A1
connection cable
38
connection block
A2
connection cable
31