The GA-10 is a gas detector meant to discover cases of gas leaks in the first phase. If gas is detected, the
EN
GA-10 will start emitting a loud alarm tone of at least 85dB (A). It's advisable to test the gas detector weekly by
using the test button. Save this manual in a secure location, like the fuse box cabinet.
RECOMMENDED INSTALLATION LOCATIONS FOR THE GA-10:
•
It's advisable to place multiple gas detectors to increase security.
•
Place at least one gas detector in the kitchen and garage, where equipment present may cause fire.
•
Usually gas will first move upwards, to the ceiling. Then it will travel horizontally. Wall-mounting may technically be pos-
sible but will result in slower alarm.
•
When mounting the detector to the ceiling, place it at a minimum distance of 50 cm from any wall and 61 cm from any
corner. Due to natural air flow, such corners will slow or prevent detection of gas.
AVOID THE FOLLOWING LOCATION INSTALLATIONS:
•
Keep away at least 3 meters from any cooking apparatus.
•
Do not place in the bathroom; hot showers may cause false alarm.
•
Do not place near a fan or near the exhaust of an airconditioner or heater.
•
Do not place in the nook of an A-shaped ceiling.
•
Do not place in rooms where the temperature can reach below 0°C or beyond 45°C.
•
Do not paint the gas detector and do not cover it in any way,
INSTALLATION INFORMATION:
Install the ceiling plate on a location fitting the description above using plugs and screws. Remove the plastic foil from
the battery, plug it in the cable located inside the battery compartment and place it firmly inside the compartment.
Once a battery is placed, you should be able to place the detector on the ceiling plate and rotate it easily. Now plug
in the adapter using the port on the side of the gas detector and plug it into a power outlet. Test the detector first by
holding the "Test"-key for 2 seconds. The GREEN LED will turn on to show the detector is operational.
9V BLOCK
60 cm minimaal
dode
luchtruimte