Download Inhoudsopgave Inhoud Print deze pagina

Status Values And Advanced Settings - Poolex Nano Action Reversible Series Gebruikershandleiding

Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

4.5

Status values and advanced settings

WARNING: This operation is used to assist servicing and future repairs.
The default settings should only be modified by an experienced professional person.
The system's settings can be checked and adjusted via the remote control by following these
steps
Step 1 : Keep pressing
Step 2 : Press
and
Step 3 : Press
to select the setting to be modified.
Note, some settings cannot be modified. Consult the settings table for further information.
Step 4 : Press
and
Step 5 : Press
to set the new value.
Step 6 : Press
to return to the main screen.
Parameter A
Parameters table
A
Water temperature
b
Evaporator temperature
c
Ambient air temperature
d
Setting temperature in heating mode
E
Defrosting mode activation timer
F
Defrosting mode maximum duration
G
Setting temperature in cooling mode
H
Adjustment of temperature difference for restart
J
Automatic restart
O
Antifreeze protection - low air temperature
P
Evaporator temperature to enter defrosting mode
U
Evaporator temperature to exit defrosting mode
t
Reserved - Do not modify
4. Use
until you enter the settings verification mode.
for see the parameters.
to adjust the setting value.
Value 26
Description
Default
Range value
value
-19~99°C
-19~99°C
-19~99°C
15~40°C
27°C
10~80 min
40 min
5~30 min
8 min
8~28°C
12°C
1~10°C
3°C
0 = OFF
1
1 = ON
-10~15°C
-5°C
-19~0°C
-3°C
1~30°C
20°C
Comment
Actual data
Actual data
Actual data
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Ajustable
Ajustable
Ajustable
Reserved