5. Technische Data & Prestatieverklaring
Manufacturer: Fireline UK Ltd, a Division of Charlton & Jenrick Ltd.
Range Designation: Purevision PVR 5 Panoramic freestanding or wall mounted stoves.
Models: Purevision PVR5, with & without Heat Exchanger Module, nominal output of 5kW.
Intended Use: Domestic heating appliances
Independently Performance & Safety tested by: Kiwa Gastec, Notified Body No: 0558
Constancy of Performance System: ISO9001
Model
Appliance weight (packed/unpacked) (Kg):
Approximate Output Range: (kW)
Harmonised EN European Standard (hEN):
Additional Characteristics Test Standard:
Additional Particulate Emission Test Standard:
Declared nominal output: (kW)
Tested nominal Output: (kW)
Tested wood re-fuelling interval: (h)
Mean CO emission (@13% O
Mean C
H
emission (@13% O
n
m
Mean NOx emission (@13% O
DIN+ particulates (@13% O
PD6434 Particulate Emissions High output: (gh
PD6434 Particulate Emissions Low output: (gh
Optical Density Time > 0.2 High (Mins)
Optical Density Time > 0.2 Low (Mins)
*Mean Flue Temperature: (Deg C)
Approximate Max Log Length: (mm)
Performance Characteristics using Maxibrite Briquetted Smokeless Fuel
Declared nominal output: (kW)
Tested nominal output: (kW)
Tested re-fuelling interval: (h)
Mean CO emission (@13% O
Mean C
H
emission (@13% O
n
m
Mean NOx emission (@13% O
DIN+ particulates (@13% O
Mean Flue Temperature: (Deg C)
Signed:
NOTE: Refuelling intervals for testing are chosen according to the standards concerned for performance testing and are
comparative only. They do not relate directly to re-fuelling intervals that can be achieved on an installed product. Re-fuelling
intervals of 1-1.5h for wood and 3-4+ hours for briquetted smokeless fuels would be more usual. Under normal conditions on a
low air control setting stoves should stay in overnight on suitable briquetted smokeless fuel.
Performance Characteristics using Wood Fuel
Test Report Issue Date:
Total Efficiency: (%)
Flue gas mass flow: (g/s)
3
) : (%) (Nmg/m
)
2
3
): (Nmg/m
)
2
3
): (Nmg/m
)
2
3
): (Nmg/m
)
2
-1
)
-1
)
Total Efficiency: (%):
Flue gas mass flow: (g/s)
3
) : (%) (Nmg/m
)
2
3
): (Nmg/m
)
2
3
): (Nmg/m
)
2
3
): (Nmg/m
)
2
Safety Distances From Combustibles
Side Wall: (mm)
Rear Wall: (mm)
Peter Mintoft
October 2016
17
Purevision
PVR 5kW
105/94
3.2 – 6.8
EN13240: 2001
Amd 2: 2004
DIN +
PD6434
10/2016
76.8
5
5.1
0.73
4.7
0.10 (1250)
45
86
13
2.3
1.5
0
0.2
302
300
81.8
5.0
5.2
1.05
3.6
0.1 (1250)
22
105
20
261
400/600
175/70
Director
Purevision PVR Cylinder Stove
Purevision
PVR 5Kw with
Notes
Heat Exchanger
105/94
3.2 – 6.8
EN13240: 2001
Amd 2: 2004
DIN +
PD6434
10/2016
83.9
5
5.9
0.74
5.3
0.10 (1250)
52
89
13
2.3
1.5
0
0.2
197
300
87.2
5.0
5.5
1.06
3.5
0.08 (1000)
15
124
25
168
400/600
175/70
Issue 02 12/16