Voorbeelden opbouw
Wall paper
6
Combustible
material
Non-combustible fire board class A1
minimum 12.5mm thickness
7
Non-combustible fire board class A1
minimal 12.5mm thickness
Wall paper
Studwork
Combustible material
Minimum 300mm
Space between wall and
steel reflector pipe 25mm
Space between studwork and
Integrated Heat Box 10mm
5
500mm is minimal space
above appliance before closed
Minimum 100mm space
Non-combustible fire board class A1
min 12.5mm thickness 250*250mm
*
Fixing hole
Space between wall and
Integrated Heat Box 10mm
No screws behind Integrated Heat Box
Space between wall and
Integrated Heat Box 10mm
No screws behind
Integrated Heat Box
Fixing points
Wall combustible ore non combustble
according local regulations
Integrated Heat Box Trimline 70 SL