OPTISONIC 8300
9.11.8 Device Root Menu (Hoofdmenu Toestel)
Snelle setup
Quick Setup (snelle setup) Language / Tag / Polling Address / <Reset Errors>
Gedetailleerde set-up
Process Input (procesingang)
Calibration (kalibratie)
Filter
Plausibility
Simulation (simulatie)
Information (informatie)
Opt
VoS monitor
(geluidssnelheid
monitoren)
Linearization (linearisatie) Linearization / Dynamic Viscosity
Opt
General
(algemeen)
Opt
P&T Correction
(P&T
correctie)
Diagnosis Value
(diagnosewaarde)
HART
I/O
Hardware
Current Output A/B/C Opt
Opt
(stroomuitgang A/B/C
Frequency Output
(Frequentie-uitgang)
Opt
A/B/D
Pulse Output A/B/D Opt
Opt
A/B/D
(Pulsuitgang)
08/2014 - 4003604701 - MA OPTISONIC 8300 en R01
BESCHRIJVING VAN DE HART-INTERFACE
Reset Counter 1 / Reset Counter 2 / Reset Counter 3
Meter Size / <Zero Calibration> / GK
Minimum Limit / Maximum Limit / Flow Direction / Time Constant /
Afslagdrempel lage flow/ Afslaghysterese lage flow
Error Limit / Counter Decrease / Counter Limit
<Simulation Volume Flow> / <Simulation Velocity of Sound>
<Sensor CPU> / <Sensor DSP> / <Sensor Driver> / <Calibration Date> /
<Calibration Date> / Serial Number Sensor / V Number Sensor
Monitor Velocity of Sound
Opt
Monitor Settings
Matching Factor / Actual Ratio Measurement/Calibration / <New Match?> /
VoS Tolerance / Time Constant
Adiabatic Index
P&T Correction / <Set P&T Correction> / P&T Inputs
Opt
Pipe Pressure
/ Density
Diagnosis 1 / <Set Diagnosis 1> / Diagnosis 2 / <Set Diagnosis 2> / Diagnosis 3 /
<Set Diagnosis 3>
Sensor serienr. / <HART eenheden uitlijnen>
Actual Flow, Corrected Flow
Unit / Format / Upper Sensor Limit / Lower Sensor Limit / Minimum Span
Terminals A / Terminals B / Terminals C / Terminals D
Cust
Range 0%
/ Range 100%
)
Cust
Error Current
/ Error Condition
Cust
Range Max
/ Polarity
Cust
LFC Threshold
/ LFC Hysteresis
Threshold Range Change
<Simulation>
Opt, Cust
Pulse Shape
/ Pulse Width
Cust
Range Min
/ Range Max
Cust
Limitation Max
/ LFC Threshold
Cust
Invert Signal
/ Special Function
<Simulation>
Opt, Cust
Pulse Shape
/ Pulse Width
Rd, Cust
Pulse Value Unit
Cust
LFC Hysteresis
/ Time Constant / Invert Signal
Opt, Cust
Phase Shift
/ <Information> / <Simulation>
Opt
Opt
Opt
Opt
, Enthalpy Flow
Cust
/ Extended Range Min
Cust
/ Measurement
Cust
Cust
/ Limitation Min
Cust
/ Time Constant
Opt, Cust
/ Hysteresis Range Change
Opt, Cust
/ 100% Pulse Rate
Cust
Cust
/ Polarity
/ Limitation Min
Cust
/ LFC Hysteresis
Opt, Cust
/ Phase Shift
Opt, Cust
/ Max. Pulse Rate
Cust
/ Value Per Pulse
/ Polarity
www.krohne.com
Opt
Opt
Opt
/ Pipe Temperature
, Mass Flow , ...
Cust
/ Extended Range Max
Cust
Cust
/ Range Min
Cust
/ Limitation Max
/
Cust
/ Special Function
Opt, Cust
/ <Information> /
Opt, Cust
/ Measurement
Cust
/
Cust
/ Time Constant /
Opt, Cust
/ <Information> /
Opt, Cust
/ Measurement
Cust
/ LFC Threshold
Cust
Opt, Cust
/ Special Function
9
Opt
/
Cust
/
/
Cust
/
Cust
/
Cust
/
Cust
/
/
135